Connector conversion box (GT11H-CNB-37S)

Specifications
■General specifications
Other specifications are the same as Handy GOT.
Item
Operating ambient
temperature
Storage ambient
temperature
Vibration resistance
■Power supply specifications
Other specifications are the same as Handy GOT.
Item
Input power supply voltage
Power consumption
Connector
conversion
box only
Inrush current
Permissible instantaneous
power failure time
■Internal relay contact specifications
Item
Operation switch
SW1 to SW6
Emergency stop switch
ES1 to ES3
Grip switch
DSW1, DSW2
Keylock switch (2-position
switch)
KSWC, KSW1, KSW2
7 OPTION AND COMMUNICATION CABLE FOR HANDY GOT
294
7.1 Connector Conversion Box
Specifications
0 °C to 55 °C
-20°C to 60°C
When installing DIN rail
Frequency
5 Hz to 8.4 Hz
8.4 Hz to 150 Hz
Specifications
24 V DC (+10% -15%)
13.7 W or less (570 mA/24 V DC) (When including the consumption current of Handy GOT)
2.2 W (90 mA/24 V DC) (When excluding the consumption current of Handy GOT)
25 A or less (at max. load) 2 ms
Within 5 ms
Contact rating
Specifications
10 mA/24 V DC
Each contact coordinates the operation switch status of Pressed (close)/Not pressed (open).
(resistance load only)
When the external cable is not connected, contacts are always open regardless of the switch status.
1 A/24 V DC
Each contact coordinates the emergency stop switch status of Pushed (open)/Return (close).
(resistance load)
When the external cable is not connected, contacts are always open regardless of the emergency
0.3 A/24 V DC
stop switch status.
(induction load)
1 A/24 V DC
Each contact coordinates the grip switch status of Pressed (close)/Not pressed (open).
(resistance load)
When the external cable is not connected, contacts are always open regardless of the grip switch
0.3 A/24 V DC
status.
(induction load)
1 A/24 V DC
Each contact coordinates the position of the keylock switch.
(resistance load)
• When the key is on the left: KSW1 and KSWC are short-circuited.
0.3 A/24 V DC
• When the key is on the right: KSW2 and KSWC are short-circuited.
(induction load)
When the external cable is not connected, contacts are always open regardless of the keylock
switch.
Acceleration
Half-amplitude
1.75 mm
2
4.9 m/s
Sweep Count
10 times each in X, Y and Z
directions