System Tone Test Call - Avaya MCC1 Maintenance Procedures

Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

3
Listen for one of the following tones:
If you get...
Reorder tone
Confirmation tone
4
Repeated test calls will alternate between out-of-service time slots on TDM bus A and TDM
bus B.

System tone test call

This test connects the voice terminal to a specific system tone.
To place the call:
1
Dial the FAC described above.
2
Dial the port network number followed by * and the two-digit tone identification number from the
following table.
3
Listen for one of the following tones:
If you get...
Intercept tone
Reorder tone
System tone
NOTE:
For a definition of call progress tones, refer to Overview for Avaya Communication
Manager, 555-233-767.
Table 88: System tone identification numbers
Number
Description
00
Null tone
01
Dial tone
02
Reorder tone
03
Alert tone
04
Busy tone
05
Recall dial tone
06
Confirmation tone
Maintenance Procedures
December 2003
Then...
There are no out-of-service time slots on the
specified port network.
Connection is made to an out-of-service time slot.
Then...
The number entered is not a valid tone number.
Inter-PN resources are not available.
The specified tone will be heard if it is functioning.
Additional maintenance procedures
Facility test calls
(1 of 3)