Replacing the S8500 dual network interface

This section describes the steps required to replace an existing dual network interface card (NIC) on the
S8500 Media Server. The control network traffic from the server out to the dedicated customer LAN
travels through the NIC. The components of this procedure include:
Backing up the Media Server
Powering down the Media Server
Removing the fan unit
Removing the old NIC
Inserting the new NIC
Replacing the fan unit
Replacing the cover and cabling
Powering up the server
Checking LED activity on the dual NIC
Confirming original Ethernet configuration
Backing up the Media Server
Backup the media server before you power it down. To backup the media server complete the following
steps:
1
Connect the services laptop to the port labeled 2 (Eth 1) on the back of the media server using the
crossover cable.
2
Open a browser window on the laptop.
3
In the address field of the browser, type in the URL for the media server and press Enter.
A welcome window opens
Maintenance Procedures
December 2003
on page 319
on page 323
on page 323
on page 324
on page 325
on page 325
on page 326
CAUTION:
Wear an antistatic wrist ground strap whenever handling the media server or its
components. Connect the strap to an approved ground, such as an unpainted metal surface.
(Figure 95, Welcome Window,
on page 321
on page 326
on page 326
on page 320).
319

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scc1Cmc1G600G650G350G700

Table of Contents