Access and login procedures
Logins and passwords on the S8100
Forced password aging (Communication
Manager-specific)
Forced password aging operates as follows:
1
The password for each login can be aged starting with the date the password was created, or
changed, and continuing for a specified number of days (1 to 99).
2
7 days before the password expiration date, the user is notified that the password is about to expire
at the login prompt.
3
When the password expires the user is required to enter a new password into the system before
logging in.
4
If a login is added or removed, the "Security Measurement" reports are not updated until the next
hourly poll, or a clear measurements security-violations command is entered.
5
Once a non-super-user has changed the password, the user must wait 24 hours to change the
password again.
Logoff notification (Communication Manager-
specific)
Security is enhanced by providing a logoff notification screen to a system administrator at log off while
either the facility test call or remote access features are still administered. The administrator can be
required to acknowledge the notification before completing the logoff process. Logoff notification is
administered on the Login Administration screen.
Super-User
S8100 is delivered to the customer with one customer "super-user" login/password defined. The
customer is required to administer additional login/passwords as needed. The super-user login has full
customer permissions and can customize any login created.
Login permissions for a specified login can be set by the super-user to block any object that may
compromise switch security. Up to 40 administration or Administer Trunks
— Additional Restrictions
— Administer Features
— Administer Permissions
Maintenance Commands
NOTE:
Enable MSP features using change system-parameters customer-options.
— Maintain Stations
— Maintain Trunks
— Maintain Systems
— Maintain Switch Circuit Packs