Additional maintenance procedures
Automatic Transmission Measurement System
Input parameters
Input
trunk addresses
full
supervision
no-selftest
no-return-loss
no-st-or-rl
repeat #
schedule
Different TTLs have different measurement capabilities, and you will need the information about specific
TTL types in
Table 96, Measurement capability by TTL type,
self-test nor does it distinguish between measurements for different test tone levels.
400
Description
Specify a single trunk or several trunks by using trunk, port, or
board addresses. These parameters are described in the
introduction to
Input parameters
group number without a member number, every member of the
group is tested.
Executes the most comprehensive test call available using the
administered test set type.
"Full" is the default.
This test takes about 10 seconds and simply confirms the presence
of testing capability at the far end.
Executes the full test, but skips self test sequences. This saves about
20 seconds on the type 105 transmission test and has no effect on
type 100 and 102 transmission tests.
Executes the full test but skips return loss sequences. This saves
about 20 seconds on the type 105 transmission test and has no
effect on type 100 or 102 transmission tests.
Executes the full test but skips the self test and the return loss
sequences. This saves about 40 seconds on the type 105
transmission test and has no effect on type 100 or 102 transmission
tests.
Specifies repeating the tests up to 99 times. The default is a single
run of the tests.
Schedule execution of the test at a later time. This is not the same as
setting up an ATMS test schedule described in
399.
on page 400. If you enter a trunk-
ATMS tests
on page
on page 401, which does not include the
Maintenance Procedures
December 2003