Additional maintenance procedures
Setting G700 synchronization
Table 97: mgp-001-1(configure)# show sync timing
Source
Primary
Secondary
Local
Comment: No failures, SIG GREEN on and ACT on when trunk is seized.
Table 98: mgp-001-1(configure)# set sync interface primary v4
mgp-001-1(configure)# show sync timing
Source
Primary
Secondary
Local
Comment: No failures, Sig is green and ACT On 2.8s off 0.2s
Note that the MM710 in slot 4 has been declared to be the primary sync source but it is not active
until the next command is issued.
Table 99: mgp-001-1(configure)# set sync source primary
mgp-001-1(configure)# show sync timing
Source
Primary
Secondary
Local
Comment: The ACT LED does not change its behavior.
NOTE:
The following command is issued from the SAT CLI, and not from the MGP CLI.
To test for slippage, from the SAT, issue the command:
test mo logical 4255 physical 1v4 test 144
410
MM
Status
Not Configured
Not Configured
v0
Active
MM
Status
V4
Locked Out
Not Configured
V0
Active
MM
Status
V4
Active
Not Configured
V0
Standby
Failure
None
Failure
None
None
Failure
None
None