Removing the fan unit
1
Locate the fan slot adjacent to the power plug on the rear of the server.
2
Remove the two screws holding the fan unit. You do not need to unplug the fan unit.
3
Set the adapter-support bracket to the right of the fan.
Removing the old NIC
1
Completely unscrew the captive screw on the left hand side of the PCI-2 slot.
The captive screw is now loose so that you can flip it up. You will need this space to maneuver the
old NIC out of its slot.
2
Firmly pull the card out of its slot.
Installing the small faceplate on the NIC
One type of NIC comes from the factory with a standard faceplate. You must remove this faceplate and
replace it with a smaller one that fits the space. See
If you have a NIC that does not require a small faceplate, proceed to
1
Using a #1 Phillips screwdriver, unscrew the two screws holding the larger faceplate.
2
Remove the faceplate from the NIC.
3
Position the small faceplate over the Ethernet ports. The faceplate must align with the screw holes
on the circuit board.
4
Screw the small faceplate onto the circuit board using the two screws removed in step 1.
Maintenance Procedures
December 2003
Figure 98, Replacing the faceplate,
Inserting the new NIC
on page 324.
on page 324.