Avaya MCC1 Maintenance Procedures page 55

Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

Table 25: Tests not executed on the G700 platform
Test
NPE_AUDIT
DS1_DTONE_TS
NEON_TEST
CLK_HEALTH
TDM_NPE_XTALK
CONF_TEST
MOD16_LOOP
GPP_LP
GPP_NPE
FT_GPP_LOOP
FT_LOOP
ICSU_LEDS
DIAL_TONE_TS
TRK_AUTO_GRD
TRK_PPM_TEST
TRK_HYB_TS
ONS_HYB_TS
BRI_EPF
L1_INQ
SSP_TDMLOOP
PRI_TSTCALL
TDMLP_BRI
PPP_TDMLOOP
Maintenance Procedures
December 2003
Notes
This test is really an audit that sends network update messages to
various ports on a board. Since the Media server does not handle
network connections for the MG, this test is not run.
DS1 CO trunk dial tone seizure test
This is run only for those boards that support the neon message lamp.
Therefore, it is not needed for R1.
Reads the LMM loss-of-clock status bits for the specified tone clock
board
Checks if the NPE chip is transmitting on more than one timeslot.
Since timeslots are not under the Media server's control, this test will
not be run.
Tests the conference circuit in the NPE. Needs the use of Timeslots;
therefore, this test is not run.
A 1004Hz reflective analog loop around on an analog port. This test
requires the use of a tone detector and all TDs are under control of the
MG.
GPP internal loopback tests is sent through both the I and S channels
for a port. A tone detector is needed to detect and report the test pattern.
The GPP NPE xtalk test. The Media server does not handle network
connections, so this test is not run.
Factory external loop around test for the GPP board.
Factory external loop around test for almost all boards.
Checks the Integrated Channel Service Unit LEDs, which do not exist
on the DS1 Media Module.
Detects dial tone.
This test is for the Australian version of the CO board, TN438.
Factory only test for certain CO trunks; requires a pulse generator.
Tests the loop around capabilities of a port's codec and hybrid circuits.
Tests the loop around capability on the codec circuit.
Electronic power feed test; not valid for TN2185.
This function actually encompasses several tests.
This is for the messaging angel, but the Media server is unaware of the
TDM bus.
Requires the use of either a data channel or a maintenance test board,
neither of which are present.
The Media server can't use the TDM bus.
The Media server can't use the TDM bus.
Maintenance strategy
G700 server-controlled maintenance
55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scc1Cmc1G600G650G350G700