For ATMS tests to run, several administrative prerequisites must be met. The following list shows the
field entries necessary to enable testing.
Table 95: ATMS administration
Form
System-parameters
customer-options
Station
Class of
Restriction
Trunk Group
Hunt Group
ATMS Trunk Test
Schedule

ATMS tests

ATMS test calls can be originated either on demand or according to the ATMS test schedule. Test
schedules are set up with test-schedule commands.
Demand test calls are originated by the test analog-testcall command. You can specify testing of an
entire trunk group, an individual trunk, or every trunk on a single circuit pack. Trunks can be addressed
by either group/member numbers or circuit pack/port locations. The type of test call, the number of the
testing line on the far-end switch and various other parameters must be administered on the Trunk Group
screen before the command can execute.
Normally you should invoke only the full or supervision tests. The other options are provided mainly for
use in setting up an ATMS schedule. The tests that are run depend on the type of TTL at the far end to
which the test call is made. The following table shows which tests are run for each type of TTL. The
command syntax is as follows:
test analog-testcall
trunkgroup#/| member#| port UUCSSpp | boardUUCSS
[full | supervision | no-selftest | no-return-loss | no-st-or-rl]
[repeat#][schedule]
Maintenance Procedures
December 2003
Field
ATMS
Extension
Port Number
Port Type COR
Facility Access Trunk
Test
Maintenance Tests
ATMS Thresholds
Additional maintenance procedures
Automatic Transmission Measurement System
Entry/Remarks
y If this field is n, contact your Avaya
representative for a change in your license file.
At least one TN711 analog port must be
assigned.
UUCSS01, where UUCSS is the location of
any TN771
105TL. The number of a COR that has testing
enabled
y
y Specifies performance thresholds, the type
and access number of the far-end TTL, and
system response to test failures.
Optional, for incoming test calls. If the system
has several TN771s, use the Hunt Group screen
to make up a hunt group of TTLs so that one
extension can be used for the whole pool.
Optional