Avaya MCC1 Maintenance Procedures page 371

Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

To test a specific time slot on the TDM bus of a specific port network:
1
Dial the FAC described in the introduction to this section and listen for dial tone.
2
Dial the 2-digit port network number followed by
Table 87, TDM Bus time slot numbers,
3
Listen for one of the following call progress tones:
If you get...
Reorder tone
Confirmation tone
System tone
NOTE:
For a definition of call progress tones, refer to Overview for Avaya Communication
Manager, 555-233-767.
TDM bus time slots
When you address a tone-carrying time slot on the TDM bus (A or B) that is currently carrying tones, you
will be connected to that time slot and will hear the tone as follows:
Time slots 005 – 021 and 261 – 277 (bus A) are reserved to carry the system's dedicated tones.
Time slots 000 – 004 and 256 – 260 (bus B) carry control information and are not addressable.
Time slots 254 and 510 are not addressable due to a hardware constraint.
At any given time, only one of the TDM busses (A or B) carries the dedicated tones, with B being the
default. Entering
tones. The corresponding time slots on the other bus are normally inactive and are only used for call
service, as a last resort, when every other non-control channel time slot on both busses is busy.
Table 87: TDM Bus time slot numbers
TDM Bus A
time slot
000
001
002
003
Maintenance Procedures
December 2003
Then...
The time slot is in use, the time slot is not addressable,
or inter-PN resources are not available to make the
call.
The time slot is idle or out-of-service. The time slot
may be on the TDM bus (A or B) that is not currently
carrying tones, or it may be busied out. The call is
connected to the time slot so that any noise may be
heard.
The time slot is carrying a system tone as listed in
Table 87, TDM Bus time slot numbers,
status port-network
will display which TDM bus is currently carrying the dedicated
TDM Bus B
time slot
Tone heard
256
Reorder
257
Reorder
258
Reorder
259
Reorder
Additional maintenance procedures
and the 3-digit time slot number listed in
#
on page 371.
(1 of 2)
Facility test calls
on page 371.
371