Output fields
Field
Trk Grp Num
Num Of Trks
Last Test Date
Last Test Time
Trunks Passed
Transm Test
Trunks Failed
Marginal
Threshld
Trunks Failed
Unaccept
Threshld
Trks In-Use
Trks Not Test
Busied Out
Trunks

ATMS detail report

This report is divided into two sections. The upper section lists the trunk group, trunk type, trunk vendor,
TTL type, and the user-defined threshold values administered on page 4 of the Trunk Group screen
(Figure 122, ATMS detail report,
measurements for each member of the trunk group selected for the report. Measurements that exceed the
marginal threshold, but not the unacceptable threshold, are highlighted. Measurements that exceed the
unacceptable threshold blink, identifying unusable trunks. When a marginal or unacceptable
measurement is found, scan the top section to find out how far the measurement deviates from its defined
threshold.
Maintenance Procedures
December 2003
Description
Results for each trunk group are listed by trunk-group number.
Only outgoing or 2-way analog trunks are listed.
The number of members in the trunk group.
The date of the oldest measurement in the trunk group.
The time of the oldest measurement in the trunk group.
The number of trunks that have passed the trunk transmission
tests.
The number of trunks that performed outside the marginal
threshold, but not the unacceptable threshold, as defined on the
Trunk Group screen.
The number of trunks that performed outside the unacceptable
threshold, as defined on the Trunk Group screen.
The number of trunks that were in use at the time of testing.
Abort codes for trunk-in-use are 1000 and 1004.
The number of trunks that were not tested due to error
conditions other than trunk-in-use. Abort codes are given in
the detailed report.
The number of trunks that were busied out in response to test
failures. These may be caused by hardware problems,
incorrect threshold values, and so on.
on page 406). The lower section lists the most recent set of
Additional maintenance procedures
Automatic Transmission Measurement System