Avaya MCC1 Maintenance Procedures page 383

Hide thumbs Also See for MCC1:
Table of Contents

Advertisement

9
Enter
add trunk
fields:
Group Type
TAC
Trunk Type
(in/out)
Port
Mode
Type
Figure 114, Trunk Group form,
2),
on page 384 show an example of the Trunk Group form.
Figure 114: Trunk Group form
display trunk-group 10
Group Number: 10
Group Name: tr 10
Direction: two-way
MIS Measured? n
Dial Access? y
Queue Length: 0
Comm Type: voice
TRUNK PARAMETERS
Trunk Type (in/out): wink/wink
Outgoing Dial Type: tone
Digit Treatment:
ACA Assignment? n
Incoming Dial Tone? y
Answer Supervision Timeout:
Maintenance Procedures
December 2003
n to add a new (test) trunk group. Then enter information for the following
tie
Use trunk access code obtained from dial plan
wink/wink
Assign two of the ports from the tie trunk.
E&M for both ports
Specify one port as t1 standard and other port as t1
compatible.
on page 383 and
TRUNK GROUP
Outgoing Display? n
Busy Threshold: 60
Internal Alert? n
Used for DCS? n
Baud Rate: 1200
Additional maintenance procedures
Analog tie trunk back-to-back testing
Figure 115, Trunk Group form - E & M mode (Page 2 of
Group Type: tie
COR: 1
Data Restriction? n
Incoming Destination:
Auth Code? n
Incoming Rotary Timeout (sec): 5
Incoming Dial Type: tone
Disconnect Timing (msec): 500
Synchronization: async
Maintenance Tests? y
Suppress # Outpulsing? n
Page
1 of
5
CDR Reports? y
TAC: 110
Night Service:
Digits:
Duplex: full
383

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scc1Cmc1G600G650G350G700

Table of Contents