Transfer Via Ethernet; Transfer Via Memory Card - YASKAWA CPU 013C Manual

For vipa system slio
Table of Contents

Advertisement

VIPA System SLIO
Approach transfer via MPI
interface

4.9.2 Transfer via Ethernet

Initialization
Transfer

4.9.3 Transfer via memory card

Proceeding transfer via
memory card
HB300 | CPU | 013-CCF0R00 | en | 16-40
1.
Connect your PC to the MPI jack of your CPU via a MPI programming cable.
2.
Load your project in the SIMATIC Manager from Siemens.
3.
Choose in the menu 'Options è Set PG/PC interface'.
4.
Select in the according list the "PC Adapter (MPI)"; if appropriate you have to add it
first, then click on [Properties].
5.
Set in the register MPI the transfer parameters of your MPI net and type a valid
address.
6.
Switch to the register Local connection.
7.
Set the COM port of the PCs and the transfer rate 38400baud for the MPI program-
ming cable from VIPA.
8.
Transfer your project via 'PLC è Load to module' via MPI to the CPU and save it
with 'PLC è Copy RAM to ROM' on a memory card if one is plugged.
So that you may access the according Ethernet interface you have to assign IP address
parameters by means of the "initialization".
X1/X2: Ethernet PG/OP channel
n
Ä Chapter 4.6 'Hardware configuration - Ethernet PG/OP channel' on page 64
1.
For the transfer, connect, if not already done, the appropriate Ethernet port to your
Ethernet.
2.
Open your project with the Siemens SIMATIC Manager.
Set via 'Options è Set PG/PC Interface' the access path to "TCP/IP ® Network
3.
card .... ".
Click to 'PLC è Download' Download ® the dialog "Select target module" is
4.
opened. Select your target module and enter the IP address parameters of the
Ethernet PG/OP channel for connection. Provided that no new hardware configura-
tion is transferred to the CPU, the entered Ethernet connection is permanently
stored in the project as transfer channel.
5.
With [OK] the transfer is started.
System dependent you get a message that the projected system differs
from target system. This message may be accepted by [OK].
® Your project is transferred and may be executed in the CPU after
transfer.
The memory card serves as external storage medium. There may be stored several proj-
ects and sub-directories on a memory card. Please regard that your current project is
stored in the root directory and has one of the following file names:
n
S7PROG.WLD
n
AUTOLOAD.WLD
1.
Start the Siemens SIMATIC Manager with your project
2.
Create with 'File è Memory Card File è New' a new wld file.
Deployment CPU 013-CCF0R00
Project transfer > Transfer via memory card
73