Deployment CPU M13-CCF0000
Project transfer > Transfer via memory card

4.9 Project transfer

Overview

4.9.1 Transfer via Ethernet

Initialization
Transfer

4.9.2 Transfer via memory card

Proceeding transfer via
memory card
68
There is the following possibility for project transfer into the CPU:
n
Transfer via Ethernet
n
Transfer via memory card
n
Option: Transfer via MPI
So that you may access the according Ethernet interface you have to assign IP address
parameters by means of the "initialization".
n
X3/X4: Ethernet PG/OP channel
Ä Chapter 4.6 'Hardware configuration - Ethernet PG/OP channel' on page 61
1.
For the transfer, connect, if not already done, the appropriate Ethernet port to your
Ethernet.
2.
Open your project with the Siemens SIMATIC Manager.
Set via 'Options è Set PG/PC Interface' the access path to "TCP/IP ® Network
3.
card .... ".
Click to 'PLC è Download' Download ® the dialog "Select target module" is
4.
opened. Select your target module and enter the IP address parameters of the
Ethernet PG/OP channel for connection. Provided that no new hardware configura-
tion is transferred to the CPU, the entered Ethernet connection is permanently
stored in the project as transfer channel.
5.
With [OK] the transfer is started.
System dependent you get a message that the projected system differs
from target system. This message may be accepted by [OK].
® Your project is transferred and may be executed in the CPU after
transfer.
The memory card serves as external storage medium. There may be stored several proj-
ects and sub-directories on a memory card. Please regard that your current project is
stored in the root directory and has one of the following file names:
n
S7PROG.WLD
n
AUTOLOAD.WLD
1.
Start the Siemens SIMATIC Manager with your project
2.
Create with 'File è Memory Card File è New' a new wld file.
3.
Copy the blocks from the project blocks folder and the System data into the wld file.
Ä Chapter 4.9.3 'Option: Transfer via MPI' on page 69
HB400 | CPU | M13-CCF0000 | en | 16-47
VIPA System MICRO