Parametrization; Status Indication - YASKAWA CPU 013C Manual

For vipa system slio
Table of Contents

Advertisement

Deployment I/O periphery
Digital output > Status indication

5.5.3 Parametrization

5.5.3.1
Address assignment
Sub module
Output address
DI24/DO16
136
137

5.5.4 Status indication

Digital output
DO +0.0 ... DO +0.7
DO +1.0 ... DO +1.3
Power supply
1L+
2L+
3L+
5L+
Error
1F
2F
on: ● | off: ○
100
Access
BYTE
BYTE
LED
Description
green
Digital output Q+0.0 ... 0.7 has "1" signal
Digital output Q+0.0 ... 0.7 has "0" signal
Digital output Q+1.0 ... 1.3 has "1" signal
Digital output Q+1.0 ... 1.3 has "0" signal
LED
Description
green
DC 24V electronic section supply
DC 24V electronic section supply not available
DC 24V power section supply outputs OK
DC 24V power section supply outputs OK
DC 24V power section supply SLIO bus OK
DC 24V power section supply SLIO bus not available
DC 24V power section supply inputs OK
DC 24V power section supply inputs not available
LED
Description
red
Error power supply sensor
no error
Error at overload respectively short circuit at the outputs
no error
Assignment
Digital output Q+0.0 ... Q+0.7 (X5)
Digital output Q+1.0 ... Q+1.3 (X5)
HB300 | CPU | 013-CCF0R00 | en | 16-40
VIPA System SLIO

Advertisement

Table of Contents
loading

This manual is also suitable for:

013-ccf0r00

Table of Contents