VIPA System SLIO
Event ID
0xE011
0xE012
0xE013
0xE014
0xE015
0xE016
0xE017
0xE018
0xE019
0xE01A
0xE01B
0xE020
0xE030
0xE033
0xE0B0
0xE0C0
0xE0CB
0xE0CC
HB300 | CPU | 013-CCF0R00 | en | 16-40
Description
ZInfo3 : Type ID
Master project engineering at slave CPU not possible or wrong slave configuration
Error at parametrization
Error at shift register access to standard bus digital modules
Error at Check_Sys
Error at access to the master
ZInfo2 : Slot of the master
ZInfo2 : Page frame master
Maximum block size at master transfer exceeded
ZInfo1 : Periphery address
ZInfo2 : Slot
Error at access to integrated slave
Error at mapping of the master periphery
Error at standard back plane bus system recognition
Error at recognition of the operating mode (8 / 9 bit)
Error - maximum number of plug-in modules exceeded
Error - Interrupt information undefined
ZInfo2 : Slot
ZInfo3 : Not relevant to the user
DatID : Interrupt type
Error of the standard bus
Internal error - Please contact the hotline!
SPEED7 is not stoppable (e.g. undefined BCD value at timer)
ZInfo1 : Not relevant to the user
ZInfo2 : Not relevant to the user
ZInfo3 : Not relevant to the user
DatID : Not relevant to the user
Not enough space in work memory for storing code block (block size exceeded)
Error at SSL access
ZInfo1 : Error
4: SSL wrong
5: Sub-SSL wrong
6: Index wrong
ZInfo2 : SSL ID
ZInfo3 : Index
Communication errors
ZInfo1 : Error code
1: Wrong priority
2: Buffer overflow
3: Telegram format error
4: Wrong SSL request (SSL ID not valid)
System specific event IDs
231