VIPA System SLIO
Name
Data type
JOB_DONE
BOOL
JOB_ERR
BOOL
JOB_STAT
WORD
Channel no. not valid
Controlling frequency
meter

5.7.5 Parametrization

5.7.5.1
Address assignment
Sub module
Input address
Counter
816
820
824
828
HB300 | CPU | 013-CCF0R00 | en | 16-40
Call the SFB. The job is processed immediately. JOB_DONE only applies to SFB
run with the result FALSE. JOB_ERR = TRUE if an error occurred. Details on the
error cause are indicated at JOB_STAT.
Address
Default
(DB)
22.0
TRUE
22.1
FALSE
24.0
0000h
1.
A new job may be started with JOB_DONE = TRUE.
2.
A value to be read of a read job may be found in JOB_OVAL in the instance DB at
address 28.
(8009h and Parameter error 8001h)
If you have preset a CHANNEL number greater than 3, the error "Channel no. not valid
" (8009h) is reported. if you have preset a CHANNEL number greater than the maximum
channel number of the CPU, "Parameter error" (8001h) is reported.
The frequency meter is controlled by the internal gate (I gate). The I gate is identical to
the software gate (SW gate).
SW gate:
open (activate): In the user program by setting SW_GATE of SFB 48
close (deactivate): In the user program by resetting SW_GATE of SFB 48
Access
DINT
DINT
DINT
DINT
Frequency measurement > Parametrization
Comment
New job can be started
Job error
Job error ID
0000h No error
0221h Integration time too low
0222h Integration time too high
02FFh Invalid job ID
8001h Parameter error
8009h Channel no. not valid
Assignment
Channel 0: Counter value / Frequency value
Channel 1: Counter value / Frequency value
Channel 2: Counter value / Frequency value
Channel 3: Counter value / Frequency value
Deployment I/O periphery
133