Deployment I/O periphery
Pulse width modulation - PWM > SFB 49 - PULSE - Pulse width modulation
Name
Declaration
OUTP_VAL
INPUT
JOB_REQ
INPUT
JOB_ID
INPUT
JOB_VAL
INPUT
STS_EN
OUTPUT
JOB_DONE
OUTPUT
JOB_ERR
OUTPUT
JOB_STAT
OUTPUT
Local data only in
Instance DB
Name
Data type
JOB_OVAL
DINT
PWM Request interface
Proceeding
140
Data type
Address
(Inst.-DB)
INT
6.0
BOOL
8.0
WORD
10.0
DINT
12.0
BOOL
16.0
BOOL
16.3
BOOL
16.4
WORD
18.0
Address
(Instance DB)
20.0
Per channel you may call the SFB in each case with the same instance
DB, since the data necessary for the internal operational are stored here.
Writing accesses to outputs of the instance DB is not permissible.
To read/write the registers of the pulse width modulation the request interface of the SFB
49 may be used.
So that a new job may be executed, the previous job must have be finished with
JOB_DONE = TRUE.
The deployment of the request interface takes place at the following sequence:
Edit the following input parameters:
Default
Comment
value
0
Output value
FALSE
Initiates the job (edge 0-1)
0
Job ID
0
Value for write jobs
FALSE
Status of the internal gate
TRUE
New job can be started.
FALSE
Job error
0
Job error ID
Default
Comment
-
Output value for read request.