10-12-09 : CD-CP00 Network Setup – IP Address
Select the IP address for the VoIP connection (default: 172.16.0.10). A static IP
address is required.
IP address is required by the CD-CP00. Some private IP network ranges (ex: 192.168.0.0/
16, 172.16.0.0/12) conflict with SIP Service Provider's Network ranges which may cause
issues when connecting SIPconnect service. Private ranges reserved for the customer's LAN
are10.x.x.x and 192.168.0.x through 192.168.10.x.
The SV8100 must be reset in order for the change to take effect.
10-12-10 : CD-CP00 Network Setup – Subnet Mask
Select the Subnet Mask to be used by the VoIP server (default: 255.255.0.0).

IPLA DSP Basic Setup

Values shown are for example purposes only. Actual IP values will be
determined by your local LAN administrator.
Figure 6 IPLA DSP Basic Setup
Port Forwarding:
The router will require port forwarding rules to be configured.
Port 5060 must be forwarded to the address entered in Program 10-12-09.
Port 5060 is not used for remote terminals – ports 5070 and 5080 are used
instead. Port 5060 is only used for trunking so there are no issues, eliminating
possible fraudulent usage of unauthorized remote attempts to register remote
terminals.