Load / Motor - Danfoss VLT FC 102 Programming Manual

Hvac drive, software version 5.41
Hide thumbs Also See for VLT FC 102:
Table of Contents

Advertisement

Parameter Lists

5.1.3 1-** Load / Motor

Paramet
Parameter description
er
number
1-0* General Settings
1-00
Configuration Mode
1-03
Torque Characteristics
1-06
Clockwise Direction
1-1* Motor Selection
1-10
Motor Construction
1-1* VVC+ PM/SYN RM
1-14
Damping Gain
1-15
Low Speed Filter Time Const.
1-16
High Speed Filter Time Const.
1-17
Voltage filter time const.
1-2* Motor Data
1-20
Motor Power [kW]
1-21
Motor Power [HP]
1-22
Motor Voltage
1-23
Motor Frequency
1-24
Motor Current
1-25
Motor Nominal Speed
1-26
Motor Cont. Rated Torque
1-28
Motor Rotation Check
1-29
Automatic Motor Adaptation (AMA)
1-3* Adv. Motor Data
1-30
Stator Resistance (Rs)
1-31
Rotor Resistance (Rr)
1-35
Main Reactance (Xh)
1-36
Iron Loss Resistance (Rfe)
1-37
d-axis Inductance (Ld)
1-38
q-axis Inductance (Lq)
1-39
Motor Poles
1-40
Back EMF at 1000 RPM
1-44
d-axis Inductance Sat. (LdSat)
1-45
q-axis Inductance Sat. (LqSat)
1-46
Position Detection Gain
1-47
Torque Calibration
1-48
Inductance Sat. Point
1-49
q-axis Inductance Sat. Point
1-5* Load Indep. Setting
1-50
Motor Magnetisation at Zero Speed
1-51
Min Speed Normal Magnetising [RPM]
1-52
Min Speed Normal Magnetising [Hz]
1-58
Flying Start Test Pulses Current
1-59
Flying Start Test Pulses Frequency
1-6* Load Depen. Setting
1-60
Low Speed Load Compensation
1-61
High Speed Load Compensation
1-62
Slip Compensation
1-63
Slip Compensation Time Constant
1-64
Resonance Dampening
1-65
Resonance Dampening Time Constant
1-66
Min. Current at Low Speed
1-7* Start Adjustments
1-70
Start Mode
1-71
Start Delay
1-72
Start Function
1-73
Flying Start
1-77
Compressor Start Max Speed [RPM]
1-78
Compressor Start Max Speed [Hz]
1-79
Compressor Start Max Time to Trip
1-8* Stop Adjustments
1-80
Function at Stop
1-81
Min Speed for Function at Stop [RPM]
1-82
Min Speed for Function at Stop [Hz]
1-86
Trip Speed Low [RPM]
1-87
Trip Speed Low [Hz]
M0010001
Programming Guide
Default value
ExpressionLimit
[3] Auto Energy Optim. VT
[0] Normal
[0] Asynchron
120 %
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Off
[0] Off
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
120 %
ExpressionLimit
ExpressionLimit
ExpressionLimit
100 %
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
100 %
100 %
0 %
ExpressionLimit
ExpressionLimit
5 ms
ExpressionLimit
[1] Parking
00 s
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
5 s
[0] Coast
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
Danfoss A/S © 10/2019 All rights reserved.
4-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
67
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
67
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
67
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
67
All set-ups
TRUE
All set-ups
TRUE
67
All set-ups
TRUE
Type
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Int16
5
5
-2
Uint16
-2
Uint16
-3
Uint16
1
Uint32
-2
Uint32
0
Uint16
0
Uint16
-2
Uint32
Uint16
-1
Uint32
-
Uint8
-
Uint8
-4
Uint32
-4
Uint32
-4
Uint32
-3
Uint32
-6
Int32
-6
Int32
0
Uint8
0
Uint16
-6
Int32
-6
Int32
0
Uint16
-
Uint8
0
Int16
0
Uint16
0
Uint16
Uint16
-1
Uint16
0
Uint16
0
Uint16
0
Int16
0
Int16
0
Int16
-2
Uint16
0
Uint16
-3
Uint8
0
Uint8
-
Uint8
-1
Uint16
-
Uint8
-
Uint8
Uint16
-1
Uint16
-1
Uint8
-
Uint8
Uint16
-1
Uint16
Uint16
-1
Uint16
293

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VLT FC 102 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents

Save PDF