Danfoss VLT FC 102 Programming Manual page 22

Hvac drive, software version 5.41
Hide thumbs Also See for VLT FC 102:
Table of Contents

Advertisement

How to Programme
Function Set-ups parameters
The Function Set-ups parameters are grouped in the following way:
2
2
Q3-10 Adv. motor settings
Parameter 1-90 Motor Thermal
Protection
Parameter 1-93 Thermistor Source Parameter 6-51 Terminal 42
Parameter 1-29 Automatic Motor
Adaptation (AMA)
Parameter 14-01 Switching
Frequency
Parameter 4-53 Warning Speed
High
Table 2.2 Q3-1 General Settings
Q3-20 Digital reference
Parameter 3-02 Minimum Reference
Parameter 3-03 Maximum Reference
Parameter 3-10 Preset Reference
Parameter 5-13 Terminal 29 Digital Input
Parameter 5-14 Terminal 32 Digital InputParameter 5-14 Terminal 32
Digital Input
Parameter 5-15 Terminal 33 Digital Input
Table 2.3 Q3-2 Open-loop Settings
Q3-30 Single zone int. setpoint
Parameter 1-00 Configuration Mode
Parameter 20-12 Reference/Feedback Unit
Parameter 20-13 Minimum Reference/Feedb.
Parameter 20-14 Maximum Reference/Feedb.
Parameter 6-22 Terminal 54 Low Current
Parameter 6-24 Terminal 54 Low Ref./Feedb.
Value
Parameter 6-25 Terminal 54 High Ref./Feedb.
Value
Parameter 6-26 Terminal 54 Filter Time
Constant
Parameter 6-27 Terminal 54 Live Zero
Parameter 6-00 Live Zero Timeout Time
Parameter 6-01 Live Zero Timeout Function
Parameter 20-21 Setpoint 1
Parameter 20-81 PID Normal/ Inverse Control
20
®
VLT
HVAC Drive FC 102
Q3-11 Analog output
Parameter 6-50 Terminal 42
Output
Output Min Scale
Parameter 6-52 Terminal 42
Output Max Scale
Q3-31 Single zone ext. setpoint
Parameter 1-00 Configuration Mode
Parameter 20-12 Reference/Feedback Unit
Parameter 20-13 Minimum Reference/Feedb.
Parameter 20-14 Maximum Reference/Feedb.
Parameter 6-10 Terminal 53 Low Voltage
Parameter 6-11 Terminal 53 High Voltage
Parameter 6-12 Terminal 53 Low Current
Parameter 6-13 Terminal 53 High Current
Parameter 6-14 Terminal 53 Low Ref./Feedb.
Value
Parameter 6-15 Terminal 53 High Ref./Feedb.
Value
Parameter 6-22 Terminal 54 Low Current
Parameter 6-24 Terminal 54 Low Ref./Feedb.
Value
Parameter 6-25 Terminal 54 High Ref./Feedb.
Value
Danfoss A/S © 10/2019 All rights reserved.
Q3-12 Clock settings
Parameter 0-70 Date and Time
Parameter 0-71 Date Format
Parameter 0-72 Time Format
Parameter 0-74 DST/Summertime Parameter 0-23 Display Line 2 Large
Parameter 0-76 DST/Summertime
Start
Parameter 0-77 DST/Summertime
End
Q3-21 Analog reference
Parameter 3-02 Minimum Reference
Parameter 3-03 Maximum Reference
Parameter 6-10 Terminal 53 Low Voltage
Parameter 6-11 Terminal 53 High Voltage
Parameter 6-12 Terminal 53 Low Current
Parameter 6-13 Terminal 53 High Current
Parameter 6-14 Terminal 53 Low Ref./Feedb. Value
Parameter 6-15 Terminal 53 High Ref./Feedb. Value
Q3-32 Multi zone/adv
Parameter 1-00 Configuration Mode
Parameter 3-15 Reference 1 Source
Parameter 3-16 Reference 2 Source
Parameter 20-00 Feedback 1 Source
Parameter 20-01 Feedback 1 Conversion
Parameter 20-02 Feedback 1 Source Unit
Parameter 20-03 Feedback 2 Source
Parameter 20-04 Feedback 2 Conversion
Parameter 20-05 Feedback 2 Source Unit
Parameter 20-06 Feedback 3 Source
Parameter 20-07 Feedback 3 Conversion
Parameter 20-08 Feedback 3 Source Unit
Parameter 20-12 Reference/Feedback Unit
Q3-13 Display settings
Parameter 0-20 Display Line 1.1
Small
Parameter 0-21 Display Line 1.2
Small
Parameter 0-22 Display Line 1.3
Small
Parameter 0-24 Display Line 3 Large
Parameter 0-37 Display Text 1
Parameter 0-38 Display Text 2
Parameter 0-39 Display Text 3
M0010001

Advertisement

Table of Contents
loading

Table of Contents