Parameter Lists
5.1.29 36-** Programmable I/O Option
Parameter
Parameter description
number
36-0* I/O Mode
36-00
Terminal X49/1 Mode
36-01
Terminal X49/3 Mode
36-02
Terminal X49/5 Mode
36-03
Terminal X49/7 Mode
36-04
Terminal X49/9 Mode
36-05
Terminal X49/11 Mode
36-1* Analog Input X49/1
36-10
Terminal X49/1 Low Voltage
36-11
Terminal X49/1 Low Current
36-12
Terminal X49/1 High Voltage
36-13
Terminal X49/1 High Current
36-14
Term. X49/1 Low Ref./Feedb. Value
36-15
Term. X49/1 High Ref./Feedb. Value
36-16
Term. X49/1 Filter Time Constant
36-17
Term. X49/1 Live Zero
36-2* Analog Input X49/3
36-20
Terminal X49/3 Low Voltage
36-21
Terminal X49/3 Low Current
36-22
Terminal X49/3 High Voltage
36-23
Terminal X49/3 High Current
36-24
Term. X49/3 Low Ref./Feedb. Value
36-25
Term. X49/3 High Ref./Feedb. Value
36-26
Term. X49/3 Filter Time Constant
36-27
Term. X49/3 Live Zero
36-3* Analog Input X49/5
36-30
Terminal X49/5 Low Voltage
36-31
Terminal X49/5 Low Current
36-32
Terminal X49/5 High Voltage
36-33
Terminal X49/5 High Current
36-34
Term. X49/5 Low Ref./Feedb. Value
36-35
Term. X49/5 High Ref./Feedb. Value
36-36
Term. X49/5 Filter Time Constant
36-37
Term. X49/5 Live Zero
36-4* Output X49/7
36-40
Terminal X49/7 Analogue Output
36-41
Terminal X49/7 Digital Output
36-42
Terminal X49/7 Min. Scale
36-43
Terminal X49/7 Max. Scale
36-44
Terminal X49/7 Bus Control
36-45
Terminal X49/7 Timeout Preset
36-5* Output X49/9
36-50
Terminal X49/9 Analogue Output
36-51
Terminal X49/9 Digital Output
36-52
Terminal X49/9 Min. Scale
36-53
Terminal X49/9 Max. Scale
36-54
Terminal X49/9 Bus Control
36-55
Terminal X49/9 Timeout Preset
36-6* Output X49/11
36-60
Terminal X49/11 Analogue Output
36-61
Terminal X49/11 Digital Output
36-62
Terminal X49/11 Min. Scale
36-63
Terminal X49/11 Max. Scale
36-64
Terminal X49/11 Bus Control
36-65
Terminal X49/11 Timeout Preset
5.1.30 40-** Special Settings
Parameter
Parameter description
number
40-4* Extend. Alarm Log
40-40
Alarm Log: Ext. Reference
M0010001
Programming Guide
Default value
[1] Voltage
[1] Voltage
[1] Voltage
[0] Voltage 0-10V
[0] Voltage 0-10V
[0] Voltage 0-10V
0.07 V
4 mA
10 V
20 mA
0 N/A
100 N/A
0.005 s
[1] Enabled
0.07 V
4 mA
10 V
20 mA
0 N/A
100 N/A
0.005 s
[1] Enabled
0.07 V
4 mA
10 V
20 mA
0 N/A
100 N/A
0.005 s
[1] Enabled
[0] No operation
[0] No operation
0 %
100 %
0 %
0 %
[0] No operation
[0] No operation
0 %
100 %
0 %
0 %
[0] No operation
[0] No operation
0 %
100 %
0 %
0 %
Default value
0 %
Danfoss A/S © 10/2019 All rights reserved.
4-set-up
Change
during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
4-set-up
Change
during
sion index
operation
All set-ups
FALSE
Conver-
Type
sion index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-2
Int16
5
-5
Int16
-2
Int16
-5
Int16
-3
Int32
-3
Int32
-3
Uint16
-
Uint8
-2
Int16
-5
Int16
-2
Int16
-5
Int16
-3
Int32
-3
Int32
-3
Uint16
-
Uint8
-2
Int16
-5
Int16
-2
Int16
-5
Int16
-3
Int32
-3
Int32
-3
Uint16
-
Uint8
-
Uint8
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
-
Uint8
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
-
Uint8
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
Conver-
Type
-1
Int16
315
5