Fujitsu PRIMERGY TX2550 M4 Upgrade And Maintenance Manual page 468

Hide thumbs Also See for PRIMERGY TX2550 M4:
Table of Contents

Advertisement

Converting a floorstand model to a rack model
Figure 332: Removing the right side cover (B)
Ê Slide the right side cover towards the server rear as far as it will go.
Ê Ensure that the three hooks on the right side cover rest in the wide ends of
the slots on the upper chassis edge (see close-up).
Ê Remove the three hooks on the right side cover from the slots on the upper
chassis edge:
Ê Using a slotted screw driver, slightly pry up on the middle hook until it
disengages (1).
Ê Pull up both ends of the right side cover to remove the left and right hooks
from the slots on the upper chassis edge (2).
Ê Ensure that all cables and components are properly secured inside the
server and that there are no loose pieces.
Ê Carefully turn the server upside down.
I
At least two people are needed to turn over a fully equipped server.
Remove HDDs and PSUs in order to facilitate the task.
468
Upgrade and Maintenance Manual
TX2550 M4