7.3.8.2

Removing a 2.5-inch HDD/SSD module

Ê Pinch the green locking clips and open the locking lever (see figure 99).
Ê Pull the HDD/SSD module out a few centimeters.
Ê Wait about 30 seconds to allow the HDD to spin down.
I
This is not necessary when removing an SSD.
I
This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the HDD to come to a stop.
Ê Pull the HDD/SSD module completely out of its bay.
7.3.8.3

Installing a 2.5-inch HDD/SSD dummy module

V
CAUTION!
If the removed HDD/SSD module is not replaced immediately, always
replace a dummy module into the unused HDD/SSD bay to comply with
applicable EMC regulations and satisfy cooling requirements.
Figure 101: Installing a 2.5-inch HDD/SSD dummy module
Ê Push the dummy module into the empty bay until it engages.
7.3.8.4

Concluding steps

Ê When working on a floorstand model, close the HDD bay cover, see section
"Installing the drive covers" on page
TX2550 M4
Hard disk drive (HDD) / solid state drive (SSD)
76.
Upgrade and Maintenance Manual