Fujitsu PRIMERGY TX2550 M4 Upgrade And Maintenance Manual page 112

Hide thumbs Also See for PRIMERGY TX2550 M4:
Table of Contents

Advertisement

Basic software procedures
Ê Choose one of the following options from the update tool menu to start the
iRMC update process:
Normal
Choose this option to update an existing system board.
Initial Choose this option if the system board has been replaced prior to the
iRMC update procedure. This option will perform all relevant flash
procedures in a row, including the iRMC firmware and bootloader.
V
CAUTION!
Do not interrupt the iRMC upgrade process after it has started. If the
process is interrupted, the iRMC may be permanently corrupted.
I
If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
Ê After completion of the flash process, remove the USB stick and restart the
server.
iRMC recovery procedure
Ê Prepare a USB stick including the bootable iRMC firmware update image.
Ê Ensure that the server has been shut down and disconnected from the
mains as described in section
Ê Connect the USB stick containing the iRMC firmware to a USB port.
Ê Connect the server to the mains while pushing the ID button on the front
panel. Ask a second person to help you if necessary.
Ê Ensure that the Global Error indicator and the ID indicator are flashing to
indicate that the server is entering the iRMC recovery state.
Ê Press the Power On/Off button. The system will start the POST process.
Ê During POST, press [F12] and select the connected USB stick as boot
device. The system will detect the USB stick.
Ê Choose the Recovery_L option from the update tool menu to start the iRMC
update process.
V
CAUTION!
Do not interrupt the iRMC upgrade process after it has started. If the
process is interrupted, the iRMC BIOS may be permanently
corrupted.
112
"Shutting down the server" on page
Upgrade and Maintenance Manual
52.
TX2550 M4

Advertisement

Table of Contents
loading

Table of Contents