Part 7: Common Reference Material

1.2.4 Forced stop deceleration function selection

(1) Parameter setting (for MR-J4-_A_series)
Abbrevi-
Number
ation
PA04
*AO
Function selection A-1
P1
This is used to select the forced stop input and forced stop deceleration function.
Setting digit
_ _ _ x
_ _ x _
_ x _ _
x _ _ _
Setting
value
0 _ _ _
2 _ _ _
POINT
With MR-J4-_A_, the deceleration to a stop function is enabled by the factory
setting. To disable the deceleration to a stop function, set [Pr. PA04] to "0 _ _ _".
Name and function
For manufacturer setting
Forced stop deceleration function selection
0: Forced stop deceleration function disabled (EM1)
2: Forced stop deceleration function enabled (EM2)
Refer to the following table for details.
EM2/EM1
selection
EM2 or EM1 is off
EM1
MBR (Electromagnetic
brake interlock) turns off
without the forced stop
deceleration.
EM2
MBR (Electromagnetic
brake interlock) turns off
after the forced stop
deceleration.
Explanation
Deceleration method
Alarm occurred
MBR (Electromagnetic
brake interlock) turns off
without the forced stop
deceleration.
MBR (Electromagnetic
brake interlock) turns off
after the forced stop
deceleration.
7 - 16
Initial
Setting
value
range
[unit]
Refer to Name and
function column.
Initial
value
0h
0h
0h
2h

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMelservo-j2m seriesMelservo-j4 seriesMr-j2s-10aMr-j2s-20aMr-j2s-40a ... Show all

Table of Contents