Motor And Control Unit - Front Door - Each - MG MG6 Series 2011 Service Manual

Table of Contents

Advertisement

Body Systems

Motor and Control Unit - Front Door - Each

Remove
1. Secure door glass in fully raised position to door frame
using adhesive tape.
2. Remove front door plastic sheet.
Plastic
Plastic
Plastic Sheet
Sheet - - - Front
Sheet
Front Door
Front
3. Loosen 2 bolts securing friction clamp to glass.
4. Remove bottom left bolt and loosen the remaining bolt
securing rear unit slide to door.
5. Lift and manoeuvre forwards rear slide from mounting
holes and lay in door.
6. Loosen bolts securing front slide to door, lift and
manoeuvre rearwards from mounting holes to access
multiplug.
7. Disconnect multiplug from door glass motor.
Version 2.0
Door Remove
Door
Remove
Remove
8. Manoeuvre and remove regulator unit through door
aperture.
Refit
1. Position and fit regulator assembly in door.
2. Connect multiplug to door glass motor.
3. Align front slide to glass and bolts into door mounting
holes.
4. Align rear slide to glass and bolts into door mounting
holes.
5. Fit bolts securing regulator assembly to door and
tighten to 6.5–7.5Nm.
6. Fit glass to regulator glass clamps, tighten bolts to
6.5–7.5Nm.
7. Remove adhesive tape securing door glass.
8. Fit front door plastic sheet.
Plastic Sheet
Plastic
Plastic
Sheet - - - Front
Sheet
Front Door
Front
9. Ensure correct operation and alignment of window.
Doors
Door Refit
Door
Refit
Refit
794