Fresh Recirculated Air Flap - Servo Motor; Distribution Flap - Servo Mmotor - MG MG6 Series 2011 Service Manual

Table of Contents

Advertisement

HVAC-ATC

Fresh Recirculated Air Flap - Servo Motor

Remove
1. Disconnect battery earth lead.
2. Remove passenger's heater closure panel.
3. Disconnect fresh recirculated air flap servo motor
multiplug.
4. Remove 3 bolts securing recirculating motor to heater
unit.
5. Disconnect recirculating motor operating lever.
6. Remove recirculating motor.
Refit
1. Fit recirculating motor and connect flap linkage.
2. Fit screws securing servo motor to heater and tighten
to9 Nm
3. Connect recirculating motor multiplug.
4. Fit passenger's heater closure panel.
5. Connect battery earth lead.
Version 2.0

Distribution Flap - Servo Mmotor

Remove
1. Remove fascia.
2. Disconnect servo motor connector.
3. Remove 3 screws securing distribution flap servo
motor.
4. Disconnect servo motor and flap linkage.
5. Remove distribution flap servo motor.
Refit
1. Fit servo motor and connect flap linkage.
2. Tighten 3 screws securing servo motor to 9 Nm
3. Connect servo motor connector.
4. Fit fascia.
HVAC System