Alarm, error and system messages
15.1 Displaying alarms
Cancel alarms
- OR -
Acknowledgement symbols
Symbol
836
4.
Press the "Save diag. data" softkey if the cause of the alarm is unknown.
The function collects all available LOG files of the operating software and
saves them to the following directory:
\user\sinumerik\didac\out_<Date-Time>.7z
5.
If there is a problem with the system, you can send the ZIP file to the
SINUMERIK hotline to help with the analysis of the problem.
In the "Cancel" column it is symbolized how you delete the pending
alarms from the alarm list.
6.
Position the cursor on an alarm.
7.
If an NCK-POWER ON alarm is displayed, turn the unit off and back on
(main switch), or press NCK-POWER ON.
- OR -
If an NC-Start alarm is displayed, press the <NC-Start> key.
- OR -
If a RESET alarm is displayed, press the <RESET> key.
- OR -
If a Cancel alarm is displayed, press the <ALARM CANCEL> key or
press the "Cancel Alarm delete" softkey.
- OR -
If an HMI alarm is displayed, press the "Delete HMI alarm" softkey.
- OR -
If a dialog alarm of the HMI is displayed, press the <RECALL> key.
- OR -
If a PLC alarm is displayed, press the key provided by the machine man‐
ufacturer.
- OR -
If a PLC alarm of the type SQ is displayed, press the "Acknowl. alarm"
softkey.
The softkeys are activated when the cursor is on the corresponding
alarm.
Meaning
NCK POWER ON
NC start
Operating Manual, 06/2019, A5E44903486B AB