Siemens SINUMERIK 840D sl Turning Operating Manual page 104

Hide thumbs Also See for SINUMERIK 840D sl Turning:
Table of Contents

Advertisement

Setting up the machine
4.4 Settings for the machine
Procedure
Resetting the actual value
NOTICE
Irreversible active zero offset
The current active zero offset is irreversibly deleted by this action.
104
1.
Select the "JOG" mode in the "Machine" operating area.
2.
Press the "Set WO" softkey.
- OR -
Press the ">>", "REL act. vals" and "Set REL" softkeys to set position
values in the relative coordinate system.
3.
Enter the new required position value for Z, X or Y directly in the actual
value display (you can toggle between the axes with the cursor keys) and
press the <INPUT> key to confirm the entries.
- OR -
Press softkey "Z=0", "X=0" or "Y=0" (if there is a Y axis), to set the re‐
quired position to zero.
Press the "Delete active WO" softkey.
The offset is deleted permanently.