Ml370 G2 Database Server - Philips M3150B Installation And Service Manual

Information center system
Table of Contents

Advertisement

Troubleshooting
Step 25. Press the keyboard F10 key to Confirm and Exit Utility.
The system will then reboot to the Windows 2000 Main Menu.
Note
If the BIOS are reset, all software (Operating System and Application) must be reinstalled.
For software installation procedures, see the IntelliVue Clinical Network Installation and
Service Manual.
ML370 G2
Database Server
Note
The following procedure only indicates changes that should be made from the system's
Default values. Unless otherwise indicated, retain the system Default settings.
Keyboard arrow keys can be used to move through menu options and change values.
Generally, the keyboard Enter key is used to select a menu item and the keyboard Esc key
is used to return to the previous item.
The following procedure describes how to set the BIOS for the Server.
Step 1. Shutdown and restart the Server to reboot it.
Note
The Press F9 Key... message of Step 2 appears only briefly so you have to be attentive. If
you miss it, reboot the Server by turning the Server Off and then On or simultaneously
pressing the keyboard Ctrl-Alt-Del keys.
Step 2. Follow the boot process carefully and watch for the Press F9 Key... message.
Step 3. Press the keyboard F9 key when the message Press F9 Key for ROM-Based
Advanced Options
Step 4. Select Advanced Options and press Enter to display its menu.
Step 5. Select Erase Non-Volatile Memory and press Enter twice to display a Yes, No
Step 6. Select Yes, Select to Erase and press Enter to display the message Power
Step 7. Turn the Server power OFF and then ON to reboot the Server.
Step 8. Repeat Step 3 during the boot process to again display the Setup menu.
Note
If the Server BIOS has not been setup before, the Select OS message will appear.
The message System Configuration Complete! appears
7-124
Maintenance, Troubleshooting, and Repair
Setup Utility appears at the top of the screen. (You may hear 2 faint beeps just
before this message appears.) The Setup menu appears.
window.
Cycle Required.
Select Windows 2000 and Press Enter. (for E.01 systems; Windows NT for others)
Press any keyboard key to display the Setup menu