AT Command Manual for Firmware L23
Parameters
<mode>
0 (default)
1
Clarification
Example: CFU interrogation for telephony service
ATD*#21*11#
*PSSSURC: 33,11,0,255,,129,0,,1,2,,1
OK
Ss_code = 33 SPS_SC_CFU
BasicServicecode = 11 SPS_BS_TELEPHONY
SsStatus = 0 SPS_STATUS_DEACTIVATED
8.3.3.
+PSSLEEP Power Management control
Description
Set sleep mode
Get current sleep mode
Get supported sleep modes
Parameters
<mode>
0,1
Clarification
Action command sets sleep mode for MT. If the command fails in an MT error, +CME ERROR: <err>
is returned. Test command returns supported values.
In <mode>=1, any character sent on the UART will wake up the system, and then AT commands can
be input normally. The module can also be waken up by a BREAK signal on the UART.
When the module is sleeping, it will set CTS to low.
+PSSLEEP parameter is saved into non-volatile memory by AT&W command. Default values are not
restored by AT&F command.
WA_DEV_WISMO_UGD_012
Description
Disable sending of additional result code
Enable sending of additional result code
Command
+PSSLEEP=<mode>
+PSSLEEP?
+PSSLEEP=?
Description
0: The module doesn‟t go in sleep mode as long as DTR is set to high level (default
value)
1: The module decides by itself (internal timing) when it goes in sleep mode
Rev 004
Proprietary AT Commands
Possible Response(s)
OK
+CME ERROR: <err>
+PSSLEEP: <mode>
OK
+PSSLEEP: (list of supported <mode>s)
OK
November 3, 2011
130