2.

Power

2.1.

Power Supply

The host provides power to the EM7690 through multiple power and ground pins as summarized in
Table
2-1.
The host must provide safe and continuous power (via battery or a regulated power supply) at all
times; the module does not have an independent power supply, or protection circuits to guard against
electrical issues.
Table 2-1
Power and Ground Specifications
Name
VCC
2, 4, 24, 38, 68, 70, 72, 74
(3.3V)
GND
3, 5, 11, 27, 33, 39, 45, 51, 57, 71, 73
2.2.

Module Power States

The module has five power states, as described in
Table 2-2
Module Power States
State
Normal (Default
State)
411139xx
202041113915
Pins
 Module is active
 Default state. Occurs when VCC is first applied,
Full_Card_Power_Off# is deasserted (pulled high), and
W_DISABLE# is deasserted
 Module is capable of placing/receiving calls, or establishing data
connections on the wireless network
 Current consumption is affected by several factors, including:
 Radio band being used
 Transmit power
 Receive gain settings
 Data rate
Rev 0.1
Rev 0.3
Specification
Min
Voltage range
3.135
Ripple voltage
-
Peak Current
-
Continuous
-
Current
-
Table
2-2.
Details
Typ
Max
Units
3.3
4.4
V
-
100
mV
-
4000
mA
TBD
-
mA
0
-