Section 14 Serial Communication Interface 3 (SCI3)
14.5.5

Simultaneous Serial Data Transmission and Reception

Figure 14.15 shows a sample flowchart for simultaneous serial transmit and receive operations.
The following procedure should be used for simultaneous serial data transmit and receive
operations. To switch from transmit mode to simultaneous transmit and receive mode, after
checking that SCI3 has finished transmission and the TDRE and TEND flags are set to 1, clear TE
to 0. Then simultaneously set TE and RE to 1 with a single instruction. To switch from receive
mode to simultaneous transmit and receive mode, after checking that SCI3 has finished reception,
clear RE to 0. Then after checking that the RDRF and receive error flags (OER, FER, and PER)
are cleared to 0, simultaneously set TE and RE to 1 with a single instruction.
Rev. 3.00 Sep. 14, 2006 Page 225 of 408