Renesas H8 Series Hardware Manual page 235

16-bit single-chip microcomputer
Hide thumbs Also See for H8 Series:
Table of Contents

Advertisement

Bit
Bit Name
3
PER
2
TEND
1
MPBR
0
MPBT
Initial
Value
R/W
Description
0
R/W
Parity Error
[Setting condition]
[Clearing condition]
1
R
Transmit End
[Setting conditions]
[Clearing conditions]
0
R
Multiprocessor Bit Receive
MPBR stores the multiprocessor bit in the receive
character data. When the RE bit in SCR3 is cleared to 0,
its state is retained.
0
R/W
Multiprocessor Bit Transfer
MPBT stores the multiprocessor bit to be added to the
transmit character data.
Section 14 Serial Communication Interface 3 (SCI3)
When a parity error is detected during reception
When 0 is written to PER after reading PER = 1
When the TE bit in SCR3 is 0
When TDRE = 1 at transmission of the last bit of a 1-
frame serial transmit character
When 0 is written to TDRE after reading TDRE = 1
When the transmit data is written to TDR
Rev. 3.00 Sep. 14, 2006 Page 205 of 408
REJ09B0105-0300