H8/3257 series, h8/325 series fp-64a user system interface cable (hs3257ech61h) for e6000 emulator (20 pages)
Summary of Contents for Renesas H8/36902
Page 1
On April 1 , 2010, NEC Electronics Corporation merged with Renesas Technology Corporation, and Renesas Electronics Corporation took over all the business of both companies. Therefore, although the old company name remains in this document, it is a valid Renesas Electronics document. We appreciate your understanding.
Page 2
Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific”...
Page 3
H8/36912, H8/36902 Group FP-32A User System Interface Cable HS36902ECH61H User’s Manual Renesas Microcomputer Development Environment System H8 Family / H8/300H Tiny Series HS36902ECH61HE Rev.1.00 2005.07...
Page 5
(iii) prevention against any malfunction or mishap. 1. These materials are intended as a reference to assist our customers in the selection of the Renesas Technology Corp. product best suited to the customer's application; they do not convey any license under any intellectual property rights, or any other rights, belonging to Renesas Technology Corp.
Renesas) pursues a policy of continuing improvement in design, performance, functions, and safety of the user system interface cable. Renesas reserves the right to change, wholly or partially, the specifications, design, user's manual, and other documentation at any time without notice.
User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole remedy for any breach of Renesas’...
Page 9
This user's manual and user system interface cable are copyrighted and all rights are reserved by Renesas. No part of this user's manual, all or part, may be reproduced or duplicated in any form, in hard-copy or machine-readable form, by any means available without Renesas’ prior written consent.
Page 10
• READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism. DEFINITION OF SIGNAL WORDS This is the safety alert symbol.
Page 11
Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance.
Page 13
The HS36902ECH61H is a user system interface cable that connects an H8/36912, H8/36902 group E6000 emulator (HS3664EPI61H or HS3664EPI62H; hereinafter referred to as the emulator) to the IC socket for an FP-32A package for the H8/36912, H8/36902 group MCU on the user system.
Section 1 Configuration... 1 Section 2 Connection Procedures ... 3 Connecting User System Interface Cable to Emulator Station ... 3 Connecting User System Interface Cable to User System ... 5 2.2.1 Installing IC Socket ... 6 2.2.2 Inserting Cable Head ... 7 2.2.3 Fastening Cable Head ...
Use an NQPACK032SA socket (manufactured by Tokyo Eletech Corporation) for the FP-32A package IC socket on the user system. Figure 1 shows the configuration of the HS36902ECH61H user system interface cable for the FP-32A package. To emulator station Screws (M2 x 6 mm) Figure 1 HS36902ECH61H User System Interface Cable Section 1 Configuration CAUTION...
Page 16
Table 1 lists the HS36902ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS36902ECH61H Components No. Component Cable body Cable head IC socket Socket cover Screws (M2 x 10 mm) Screws (M2 x 6 mm) CTS screws (M3 x 6 mm) Screwdriver Documentation...
Section 2 Connection Procedures Connecting User System Interface Cable to Emulator Station Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
Page 18
Emulator station Cable body connector CTS screws (M3 x 6 mm) User system interface cable Figure 2 Connecting User System Interface Cable to Emulator Station...
Connecting User System Interface Cable to User System Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
2.2.1 Installing IC Socket After checking the location of pin 1 on the IC socket fasten it to the user system before soldering. After confirming the location of pin 1 on the IC socket, apply epoxy resin adhesive to the end of the four projections at the bottom of the IC socket, and fasten it to the user system.
Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets. (Use slightly more solder than the MCU.) 2.2.2 Inserting Cable Head Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-32A package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 4.
Page 22
Fasten the user system interface cable head to the IC socket for an FP-32A package on the user system with the two screws (M2 time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components.
2.2.4 Fastening Cable Body Connect the cable body to the cable head. Removing Cable body Push the unfastening jigs. Remove jig Cable head User system Figure 5 Fastening Cable Body...
Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-32A package (NQPACK032SA: manufactured by Tokyo Eletech Corporation). Note that the dimensions in figure 6 are somewhat different from those of the actual chip's mount pad.
Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. 16.7 24.6 66.0 Unit: mm ± Tolerance: 0.5 mm Figure 7 Dimensions for User System Interface Cable Head...
Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 8. Cable head User system Figure 8 Resulting Dimensions after Connecting User System Interface Cable IC socket (NQPACK032SA manufactured by...
Section 3 Installing the MCU to the User System 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screws. 3. The tightening torque must be 0.098 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
Page 28
Figure 9 Installing MCU to User System Screws (M2 x 6 mm) IC socket (NQPACK032SA manufactured by Tokyo Eleteck Corporation) User system Socket cover Pin 1...
Section 4 Verifying Operation 1. Turn on the emulator according to the procedures described in the H8/3664 E6000 Emulator User’s Manual (HS3664EPI61HE-U2 or HS3664EPI62HE-U2). 2. Verify the user system interface cable connections by accessing ports and checking the bus states of the pins. If an error is detected, recheck the soldered IC socket and the location of pin 3.
Page 30
Figure 10 shows the system clock oscillator on the user system interface cable and the subclock input specifications. R1 1 M HCU04 To E6000 emulator HCU04 R2 270 OSC1 OSC2 System clock oscillator Figure 10 System Clock Oscillator and Subclock Input Specifications R5 3.3 M R13 10 k R12 2.2 k...
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU.
Page 32
6. The P1 short connector is used for testing. Do not remove the inserted jumper pin. Figure 12 P1 Short Connector...
Page 33
7. SW1 and SW2 are used to switch OSC2 or PC1 and OSC1 or PC0. Turn SW1 and SW2 to the OSC1 and OSC2 sides, respectively, when they are used as OSC1 and OSC2. Turn SW1 and SW2 to the PC0 and PC1 sides, respectively, when they are used as PC0 and PC1. At shipment, SW1 and SW2 are turned to the OSC1 and OSC2 sides.
Page 35
User System Interface Cable HS36902ECH61H Publication Date: Rev.1.00, June 22, 2005 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co., Ltd. 2005. Renesas Technology Corp. All rights reserved. Printed in Japan.
Page 36
Nippon Bldg., 2-6-2, Ohte-machi, Chiyoda-ku, Tokyo 100-0004, Japan http://www.renesas.com RENESAS SALES OFFICES Refer to "http://www.renesas.com/en/network" for the latest and detailed information. Renesas Technology America, Inc. 450 Holger Way, San Jose, CA 95134-1368, U.S.A Tel: <1> (408) 382-7500, Fax: <1> (408) 382-7501 Renesas Technology Europe Limited Dukes Meadow, Millboard Road, Bourne End, Buckinghamshire, SL8 5FH, U.K.
Page 37
H8/36912, H8/36902 Group FP-32A User System Interface Cable HS36902ECH61H User’s Manual 1753, Shimonumabe, Nakahara-ku, Kawasaki-shi, Kanagawa 211-8668 Japan REJ10B0198-0100...