Reply Commands [Recv Command Edit] - IDK MSD-5401 User Manual

Presentation switcher
Table of Contents

Advertisement

8.12.2 Reply commands [RECV COMMAND EDIT]

You can register up to 32 commands.
Item
Set the number of bytes from the first byte to be
SIZE
compared.
Select "STOP" (to stop the next operation), "EXEC" (to
execute it), or "RETRY" (to send the command again)
PROCESS
for when received data and reply command data match.
Select whether PJLink commands are set or not for
PJLink
when input reply command data is input.
Select the input mode of reply command data.
"ASCII": For data consisting of only 0A, 0D, 20 to 7D
COMMAND
INPUT MODE
(text)
"HEX": For data including other codes
Set the command to be compared with the received
data from the first byte to the byte count set in "SIZE". If
using alphabets (A to Z, a to z), make sure to
DATA
distinguish capital and lower case letters. (Up to 30
bytes)
Received data is compared with MASK DATA without
"AND" of each bit and reply command data. (Use this
MASK
item to determine the state using the received data bit.)
Register a note up to 14 characters.
MEMO
When reply command is received, the registered note is
displayed.
[Table 8.19] Setting items of reply commands
Description
Those default values do not apply to reply commands 31 and 32.
171
Range
0 to 30 bytes
[Default]: 0 byte
STOP
EXEC [Default]
RETRY: Resend commands
OFF [Default]
ON
ASCII [Default]
HEX
0A, 0D, and 20 to 7D of "9
ASCII codes" or
00 to FF (Hex)
[Default]: 20 (Space)
(Values described above all
with hex)
00 to FF (Hex)
[Default]: All: "FF"
20 to 7D of "9 ASCII codes"
except for 2C (,) [Default]: All:
Spaces

Advertisement

Table of Contents
loading

Table of Contents