Set the delimiter to be sent at the end of the received
data.
"NONE": delimiter is not checked and all received data
DELIMITER
*1 *2
within the set timeout will be valid.
Value other than "NONE": delimiter is checked and
data received before delimiter will be valid.
*1
RCV CHECK
Set whether reply command that may be returned is
*3
checked or not.
Set the timeout time for reply command to a sent
TIME OUT
command.
*1 *4 *5
Set the number of retries to resend the same
*1 *4 *5
RETRY
command again if no valid response is replied.
Set the retry interval to resend the command.
*1 *4 *5
INTERVAL
Set whether the next command is to be executed or
*1 *4 *5
ERROR
not if no valid response is replied, even after
completing retry for the set number of retries.
Set the control of pins 22 to 24 and 47 to 49 of Tally
Tally output
output.
*8
"TGL" (toggle operation): contact points are switched
control
from OFF to ON or vice versa.
Set the waiting time before the status is put back after
*8
PULSE
controlling contact points with Tally output.
HDMI CEC
Set the CEC control for the display devices connected
*9
control
to HDMI connectors of OUT1 to OUT4.
Set whether the next command is executed or not if no
Process for CEC
response is replied from the display device that is
*9
error
controlled with CEC.
Register a note up to 14 characters.
MEMO
The registered note is displayed when the control
command is executed.
1
If "Port" is set to "Tally" or "CEC", you do not need to set this item.
*
2
If "RECV DISPLAY" is set to "OFF", you do not need to set this item.
*
3
If "RECV DISPLAY" is set to "ASCII" or "HEX", you do not need to set this item.
*
4
If only "LOOP BACK" of communication ports is set to "ON", you do not need to set this item.
*
5
If all "RCV CHECK" is set to "NOT CHECK", you do not need to set this item.
*
6
If either "RS-1" or "RS-2" is set to "ON", set "8.10.2 Operation mode" to "TRANSMITTER".
*
7
If any LAN connections for "LAN1" to "LAN8" are set to "ON", set "8.11.4 Operation mode" to
*
"TRANSMITTER".
8
If "PORT" is set to "COM" or "CEC", you do not need to set this item. For Tally output pins that are set to
*
"Not control", set "8.15.1 Assigning functions" to "Control command output".
9
If "PORT" is set to "COM" or "Tally", you do not need to set this item.
*
160
MSD-54 SERIES User's Guide
NONE [Default]
00 to FF (Hex)
CHECK [Default]
NOT CHECK
0 ms. to 99 seconds and 999
ms.
[Default]: 0 ms.
0 to 99
[Default]: 0
0 ms. to 99 seconds and 999
ms.
[Default]: 0 ms.
STOP: [Default]
EXEC: Continue
-: Not control [Default]
OFF
ON
TGL
NONE: Eternal [Default]
100 ms. to 9990 ms. (by 10
ms.)
-: Not control [Default]
POWER OFF
POWER ON
STOP [Default]
EXEC: Continue
20 to 7D of "9 ASCII codes"
except for 2C (,)
[Default]: All spaces