IDK MSD-5401 User Manual page 268

Presentation switcher
Table of Contents

Advertisement

Problem
Control using Tally
cannot be performed.
Control through CEC
cannot be performed.
Parallel input/Tally output
The MSD cannot be
controlled from
parallel input.
Even though only
one operation is
performed from
parallel input, the
same operation is
performed for several
times.
Even though rotary
encoder is moved
slightly, the setting is
changed.
The settings are not
changed unless the
rotary encoder is
moved significantly.
Others
Input signals
temporarily
disappear when IN1
to IN 5 are switched.
Devices cannot be
controlled through
CEC.
Is Tally output connecter's FUNCTION ASSIGN set to "PRESET
COMMAND"?
If not, set it to "PRESET COMMAND".
Do you use cables supporting CEC?
For CEC control, an HDMI cable supporting CEC is required.
Does the display device support CEC? Is the HDMI association function
of the display device set correctly?
Enable the HDMI link control and Power on association function (for
turning on the display device by external devices) of the display device.
Are operations from parallel input locked? They must be unlocked.
Are functions of the parallel input connector already assigned?
If control command is executed from parallel input, operations from the
parallel input are disabled until execution of control commands finishes or
"INVALID TIME" passes.
Immediately after starting-up, operations from parallel input are disabled
until connection of the display device is confirmed.
Set the time period for "CHATTERING FILTER".
Set the number of clicks (ROTARY ENCODER).
When the CEC connection changes, EDID may change. In this case,
input signals are interrupted. Check the connection settings.
Are HDMI cables supporting CEC being used?
To use CEC, enable HDMI link control of the connected devices (such as
LCD TVs, Blu-ray recorder, and so on).
Cause/Check item/Solution
268
MSD-54 SERIES User's Guide
Page
212
170
205
195
180
208
204
119
119

Advertisement