IDK MSD-5401 User Manual page 97

Presentation switcher
Table of Contents

Advertisement

The right and bottom edges are cut off and automatic
measurement is performed with "NORMAL MODE".
If the total number of horizontal dots is not correct, the aspect ratio is not matched even though automatic
measurement is set to perform with the "NORMAL MODE". In this case, select "NEXT ASPECT" (Auto
measurement taking into account aspect ratio) for the measurement function. Each time you press the "SET"
key, input timing is set based on several aspect ratios of the input signals. If the aspect ratio of the input signal
is known, you can directly specify the aspect ratio to correctly perform the automatic measurement.
If input signal is not registered in the MSD, use this function.
If you set only start position, the message, "NORMAL END" is displayed. If the
display period is changed with "NORMAL MODE" or if you specify "NEXT ASPECT"
or aspect ratio directly, the set resolution is displayed.
In case the aspect ratio does not match or video is displayed on the position far from the correct position, set
the input timing in "8.6.1 The total number of horizontal dots", "8.6.2 Horizontal start position", "8.6.3
Horizontal display period", "8.6.4 Vertical start position", and "8.6.5 Vertical display period".
You can execute the automatic measurement not only from this menu but also by pressing an input selection
key (one of IN6 to IN9 keys) for 2 seconds or longer. By pressing an input selection key for 2 seconds, the
auto measurement mode with "NORMAL MODE" will be enabled. After that, pressing the same key for 3
seconds or longer, the auto measurement mode with "NEXT ASPECT" will be enabled. (This auto
measurement mode can be enabled also by pressing the input key for 5 seconds or longer continuously.)
Once you perform the function, from the next time, it can be performed simply by pressing the key without
pressing it for several seconds. This mode can be canceled 5 seconds after the last auto measurement is
executed. If you execute the automatic measurement with this mode, the input selection keys blink until the
measurement finishes.
You can execute the automatic measurement also from input selection keys of parallel input.
[Figure 8.37] Automatic measurement with "NORMAL MODE"
Each time auto measuring is performed, input timing is set in order from some aspect ratios.
[Figure 8.38] Auto measurement with "NEXT ASPECT"
If display period is not correct and edges are cut off (even
if the shift starting position is correct), the display period
will be set automatically.
97
[IN6 AUTO SETUP]
1024x 768 60.00Hz

Advertisement

Table of Contents
loading

Table of Contents