Identification & Maintenance Data (I&M) - Siemens SINAMICS G120 Operating Instructions Manual

Low voltage inverters built-in units with cu250s-2 control units and encoder evaluation
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

8.3
Identification & maintenance data (I&M)
I&M data
The inverter supports the following identification and maintenance (I&M) data.
I&M
data
I&M0
I&M1
I&M2
I&M3
I&M4
When requested, the inverter transfers its I&M data to a higher-level control or to a PC/PG with
installed STEP 7 or TIA Portal.
I&M0
Designation
Manufacturer-specific
MANUFACTURER_ID
ORDER_ID
SERIAL_NUMBER
HARDWARE_REVISION
SOFTWARE_REVISION
REVISION_COUNTER
PROFILE_ID
PROFILE_SPECIFIC_TYPE
IM_VERSION
IM_SUPPORTED
Converter with the CU250S-2 Control Units
Operating Instructions, 04/2018, FW V4.7 SP10, A5E31759476B AG
Format
Explanation
u8[64] PROFIBUS
Inverter-specific data, read only
u8[54] PROFINET
Visible String [32]
Plant/system identifier
Visible String [22]
Location code
Visible String [16]
Date
Visible String [54]
Any comment
Octet String[54]
Check signature to track changes
for Safety Integrated.
This value can be changed by the
user.
The test signature is reset to the
value generated by the machine
is p8805 = 0 is used.
Format
u8[10]
u16
Visible String
[20]
Visible String
[16]
u16
char, u8[3]
u16
u16
u16
u8[2]
bit[16]
Alarms, faults and system messages
8.3 Identification & maintenance data (I&M)
Associated pa‐
rameters
-
p8806[0 ... 31]
p8806[32 ... 53] "sc2+or45"
p8807[0 ... 15]
p8808[0 ... 53]
p8809[0 ... 53]
Example for the
Valid for PRO‐
content
FINET
00 ... 00 hex
42d hex (=Sie‐
mens)
„6SL3246-0BA22-
1FA0"
„T-R32015957"
0001 hex
„V" 04.70.19
0000 hex
3A00 hex
0000 hex
01.02
001E hex
Example for the
content
See below
"ak12-
ne.bo2=fu1"
"2013-01-21
16:15"
-
Values of
r9781[0] and
r9782[0]
Valid for PRO‐
FIBUS
---
393