4.3.2

SERVICE TOOL maintenance data

Description of function
For maintenance purposes, the SIDOOR controller determines operating data of the controller,
the motor and the door mechanics. These values can be used to determine the service life and
frequency of use. In addition, changes in the driving characteristics of the motor and the door
can be detected and evaluated for maintenance purposes.
The maintenance data can be queried via the SIDOOR SERVICE TOOL (Page 144) or the SIDOOR
SUPPORT app (Page 151). As of FW version V01.48, SIDOOR AT40 CAN ADV provides the
maintenance data via the CANopen interface.
Via "MAIN MENU -> General setup -> Special parameters -> CAN Cond. Monitoring", transfer of
the maintenance data by MPDOs can be activated for AT40 CAN ADV.
The MPDO data is transmitted after each complete door cycle.
You will find information about manufacturer-specific CANopen objects at Industry Online
Support on the Internet (https://support.industry.siemens.com/cs/ww/en/ps/18268/man).
Note
The transfer of the maintenance data via the CANopen protocol has been modified in the
firmware version AT40 V1.49 to the new CANopen standard for "Condition Monitoring" CiA 417,
Part 4. Therefore, the transfer of the maintenance data via CANopen is no longer compatible
with the firmware predecessor version, AT40 V1.48.
4.3.2.1

Operating data

Based on the operating data, the service life and frequency of use of the engine and the door
control unit can be determined and evaluated for maintenance purposes. The operating data
can be queried via the operating menu (see "Service -> Maintenance data -> Operating data").
The operating data can be deleted via the operating menu (see "Service -> Maintenance data -
> Delete operating data").
Note
The operating hours counter cannot be deleted.
The following operating data are determined:
• Number of openings
• Number of obstructions
• Number of learn runs
• Number of power failures
• Number of operating hours
AT40 and ATD400V for elevators