Siemens SINAMICS G120 Operating Instructions Manual page 68

Low voltage inverters built-in units with cu250s-2 control units and encoder evaluation
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Installing
4.3 Installing Power Modules
Table 4-6
Frame
size
FSA ...
FSC
The Power Module is designed for mounting without any lateral cooling air clearance. For tolerance
1)
reasons, we recommend a lateral clearance of 1 mm.
Table 4-7
Frame
size
FSA
FSB
FSC
66
Cooling air clearances and additional dimensions
Power Module depth [mm]
171
Electrical cabinet cutout and mounting holes
Control cabinet cutout [mm]
a
b
c
103
106
27
148
134
34.5
123
174
30.5
T1
T2
118
53
d
e
198
88
304
116
365
156
Converter with the CU250S-2 Control Units
Operating Instructions, 04/2018, FW V4.7 SP10, A5E31759476B AG
Cooling air clearances [mm]
Top
Bottom
Front
80
100
Fixing/torque [Nm]
8 × M5 / 3.5
8 × M5 / 3.5
10 × M5 / 3.5
1)
100

Advertisement