Siemens SINAMICS G120 Operating Instructions Manual page 464

Low voltage inverters built-in units with cu250s-2 control units and encoder evaluation
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Technical data
10.3 Technical data, PM240-2 Power Modules
Table 10-26 PM240-2, IP20, frame size E, 380 V ... 480 V 3 AC
Article No. without filter
Article No. with filter
LO base load power
LO base load input current
LO base load output current
HO base load power
HO base load input current
HO base load output current
Fuse according to IEC
Fuse according to UL, class J
Power loss without filter
Power loss with filter
Required cooling air flow
Weight without filter
Weight with filter
Table 10-27 PM240-2, PT, frame size E, 380 V ... 480 V 3 AC
Article No. without filter
Article No. with filter
LO base load power
LO base load input current
LO base load output current
HO base load power
HO base load input current
HO base load output current
Fuse according to IEC
Fuse according to UL, class J
Power loss without filter
Power loss with filter
Required cooling air flow
Weight without filter
Weight with filter
Approx. 1.4 kW through the heatsink
1)
462
6SL3210-1PE28-8UL0
6SL3210-1PE28-8AL0
45 kW
86 A
90 A
37 kW
78 A
75 A
3NA3832 (125 A)
125 A
1.29 kW
1.30 kW
83 l/s
26 kg
28 kg
6SL3211-1PE31-1UL0
6SL3211-1PE31-1AL0
55 kW
104 A
110 A
45 kW
94 A
90 A
3NA3836 (160 A)
150 A
1.65 kW
1)
1.67 kW
1)
83 l/s
30.5 kg
32 kg
Operating Instructions, 04/2018, FW V4.7 SP10, A5E31759476B AG
6SL3210-1PE31-1UL0
6SL3210-1PE31-1AL0
55 kW
104 A
110 A
45 kW
94 A
90 A
3NA3836 (160 A)
150 A
1.65 kW
1.67 kW
83 l/s
26 kg
28 kg
Converter with the CU250S-2 Control Units

Advertisement

Table of Contents
loading

Table of Contents