Frame sizes FSD ... FSF
Table 4-3
Frame
size
FSD
FSE
FSF
FSG
BOP-2, IOP-2 or blanking cover
1)
Power Module depth without Control Unit: FSD, FSE 237 mm, FSF 357 mm, FSG 358 mm
2)
Table 4-4
Frame
size
FSD
FSE
Converter with the CU250S-2 Control Units
Operating Instructions, 04/2018, FW V4.7 SP10, A5E31759476B AG
Dimensions depend on the operator panel (OP) that is inserted
Width
Height [mm]
[mm]
without shield
plate
200
472
275
551
305
709
305
1000
Drilling dimensions, cooling clearances and fixing
Drilling dimensions [mm]
h
b
c
430
170
7
509
230
8.5
Mounting depth in the cabinet with
with shield plate
without OP
624
728
965
1286
Cooling air clearances [mm]
Top
Bottom
Front
2)
2)
300
350
300
350
Installing
4.3 Installing Power Modules
1)
Control Unit (CU) [mm]
2)
with OP
256
267
256
267
376
387
376
387
Fixing/torque [Nm]
1)
100
4 x M5 / 6.0
100
4 x M6 / 10