Sign In
Upload
Manuals
Brands
Lucent Technologies Manuals
Network Hardware
Stinger MRT-AD-36S-8E1
Lucent Technologies Stinger MRT-AD-36S-8E1 Manuals
Manuals and User Guides for Lucent Technologies Stinger MRT-AD-36S-8E1. We have
1
Lucent Technologies Stinger MRT-AD-36S-8E1 manual available for free PDF download: Getting Started Manual
Lucent Technologies Stinger MRT-AD-36S-8E1 Getting Started Manual (191 pages)
Brand:
Lucent Technologies
| Category:
Network Hardware
| Size: 3.45 MB
Table of Contents
Customer Service
3
Table of Contents
5
About this Guide
15
Documentation Conventions
15
What Is in this Guide
15
What You Should Know
15
Stinger Documentation Set
16
Introduction to the Stinger MRT
19
The Stinger MRT
19
Virtual Slot Conventions for the Stinger MRT
19
Stinger MRT Models
20
Table 1-1 Stinger MRT Virtual Slots
20
Table 1-2 Stinger MRT Models
20
Before You Begin
21
Preparing for the Installation
21
Selecting an Installation Site
21
Preventing Static Discharge Damage
22
Required Tools and Equipment
22
Use a Wrist Strap
22
Figure 2-1 Wrist Grounding Strap
23
Figure 2-2 Wrist Strap Plugged into a Grounding Jack
23
Remove Plastics from Your Work Area
24
Store Components Properly
24
Unpacking the Stinger MRT
24
Verifying the Hardware Configuration
24
Figure 2-3 Stinger MRT Connectors
25
Stinger MRT Interfaces
25
STS-3 Cascading Connectors
25
Trunk Module Location
25
DS3-ATM Trunk Modules
26
Figure 2-5 OC3-ATM Trunk Module Fiber Optic Connection Points
26
OC3/STM1-ATM Trunk Modules
26
Figure 2-6 DS3-ATM Trunk Module Connection Points
27
Figure 2-7 T1 or E1 Trunk Module
27
T1 and E1 Trunk Modules
27
Before You Begin
29
Installing a Stinger MRT
29
Setting up the Unit
29
Figure 3-1 Stinger MRT Mounting Brackets
30
Figure 3-2 Installing Mounting Brackets
30
Installing the Mounting Brackets
30
Mounting the Unit in a 23-Inch Rack
30
Installing and Removing Trunk Modules
31
Installing the Stinger into a 23-Inch (58.42Cm) Cabinet
31
Figure 3-4 Installing a Trunk Module
32
Installing a Trunk Module
32
Removing a Trunk Module
32
Connecting Cables to a Stinger MRT Unit
33
Connecting the Subscriber Lines
33
Connecting the POTS Lines
34
Figure 3-5 Connecting the Subscriber Lines
34
Connecting the STS-3 Cascading Connections
35
Figure 3-6 Connecting the POTS Lines
35
Connecting the Trunk Module
36
Figure 3-7 Connecting the STS-3 Cascading Connection
36
OC3/STM1-ATM Trunk Module Connections
36
DS3-ATM Trunk Module Connections
37
Figure 3-8 Connecting an OC3-ATM Trunk Module
37
Figure 3-9 Connecting DS3-ATM Trunk Modules
37
T1 or E1 Trunk Module Connections
37
Figure 3-10 Connecting a T1 or E1 Trunk Module
38
Network Management Connections
38
System Clocking
38
Alarm Monitoring
39
Connecting a Stinger MRT to Monitor the Alarm Status of Other Devices
39
Connecting to Monitor Stinger MRT Alarm Status
39
Table 3-1 Alarm Connector Pinouts for Stinger MRT Alarms
39
Table 3-2 Alarm Connector Pinouts for Monitoring the Alarm Status of Remote Devices
40
What's Next
40
Before You Begin
41
Connecting Power to a Stinger MRT Unit
41
Determining the Operating Status
41
Power Requirements
41
Figure 4-1 Removing the Power Terminal Shield
42
Figure 4-2 Connecting the -48Vdc Power Filters
43
Turning off Power to a Stinger MRT Unit
43
Turning on Power to a Stinger MRT Unit
43
Activity Lights
44
Figure 4-3 Stinger MRT Status Lights
44
Table 4-1 Status Lights on the Stinger MRT
44
What's Next
45
Figure 5-1 Example of DSLAM Operations
47
Stinger MRT Operation as a DSL Access Multiplexer
47
Stinger MRT Operational Overview
47
Administrative Configuration
48
Stinger MRT ATM Switching Overview
48
Stinger MRT Configuration Overview
48
Line Configuration
49
System Clocking Modes
49
Trunk Module Configuration
49
Onboard Flash Memory and Software Updates
50
RADIUS Support
50
SNMP Support
50
Stinger MRT Management Features
50
Using the Command-Line Interface
50
Tracking System Activity
51
Table 5-1 Location of Configuration Information
52
What's Next
52
Administrative Configuration Overview
53
Configuring Administrative Access, System Timing, and Startup Settings
53
Making the Initial Administrative Connection
53
Figure 6-1 Serial Management Connection to the Stinger MRT
54
Logging into the Stinger MRT
54
Changing Defaults for Serial-Port Logins
55
Restricting Administrative Access
55
Changing the Default Admin Password
56
Setting a Telnet Password
56
Providing a Basic System IP Configuration
57
Figure 6-2 Default Netmask for Class C IP Address
58
IP Address Syntax
58
Netmasks
58
Subnets
58
Table 6-1 IP Address Classes and Number of Network Bits
58
Table 6-2 Decimal Subnet Masks and Prefix Lengths
59
Assigning the Ethernet IP Addresses
60
Configuring a Default Route
60
Additional Administrative Connections and Configuration
61
Connecting to an Ethernet LAN
61
Figure 6-3 Local Backbone Router to be Used as Default Route
61
Connecting to and Configuring an External Modem
62
Figure 6-4 Ethernet Connection
62
Verifying a LAN Connection for Administrators
62
Connecting to and Configuring an Internal Modem
63
Figure 6-5 Administrative Connection with a Modem to the Stinger MRT Unit
63
Configuring an Internal Modem
64
Figure 6-6 Connection for Internal Modem
64
Figure 6-7 Terminating ATM Connection
65
Overview of a Terminating ATM Connection
65
Terminating PVC Administrative Connections
65
Overview of Terminating PVC Settings
66
Typical Terminating PVC Configuration for an Administrative Connection
67
Figure 6-8 Management Connection from a Remote Network
68
Checking the Status of a Terminating PVC
69
Configuring System Clocking (Optional)
70
Using the BITS Clock Source
70
Changing the BITS Clock Source
71
Loss of BITS Signal Indications and Fall-Back
71
Configuring Trunk Ports as Eligible Clock Sources
72
Using a Trunk Module Clock Source
72
Retaining Basic Configuration Settings for Remote Administration
73
Typical Trunk Port Clock Source Configurations
73
Allowing Password Information in the Default.cfg File
74
Creating the Default.cfg File
74
Storing a Partial Configuration for Restart after Clearing NVRAM
74
Restarting with a Partial Configuration
75
Chapter 7 Configuring the ADSL Line Interfaces
77
Configuring ATM ADSL-DMT Interfaces
77
Overview of the AL-DMT Profile
77
ADSL Protocol Support
78
Line Activation and DMT Parameters
78
AL-DMT Profile
78
Line-Config Subprofile
79
Rate-Adaptive Mode Parameters
81
Power-Level Parameters and Power Spectral Density (PSD)
82
Fast and Interleaved Bit-Rate Parameters
83
Fast-Path-Config Subprofile
83
Interleave-Path-Config Subprofile
84
Margin-Config Subprofile
86
Figure 7-1 Relationship between Noise Margin Parameters and Power Adjustments
86
Configuring Call Control
87
Examples of ADSL-DMT Interface Configuration
89
Figure 7-2 ADSL ATM Configuration
89
Checking the Status of an ADSL-DMT Interface
90
Checking Status of the Physical Interface
90
Obtaining Statistics about Operations
92
Displaying ADSL-DMT Port Status and Nailed Groups
94
Chapter 8 Configuring T1 and E1 Trunk Modules
95
Introducing the T1 and E1 Trunk Modules
96
Checking the Base Profile for Software Licenses
96
Verifying the Eight-Port License
96
Verifying the IMA License
96
Overview of Supported Features
97
Figure 8-1 T1 or E1 Trunk Module for the Stinger MRT
97
Installing a T1 or E1 Trunk Module
98
Connecting a T1 or E1 Trunk Module
98
Interpreting T1 or E1 Module Status Lights
98
Figure 8-2 Connecting a T1 or E1 Trunk Module
98
Table 8-1 T1 and E1 Trunk Module Port Connector Status Lights
98
Profiles Associated with a T1 or E1 Module
99
DS1-ATM Profile
100
DS1-ATM-Stat Profile
105
Slot-Static-Config Profile
109
Imagroup Profile
110
IMAHW-Config Profile
114
IMA-Group-Stat Profile
116
Connection Profile
120
Configuring T1 or E1 Module Connections
123
Typical UNI Configuration
124
Figure 8-3 Sample UNI Configuration Links
124
Typical IMA Configuration
126
Typical Return to UNI Configuration from IMA
128
Considerations for Assigning a Nailed Group Number to a DS1-ATM Profile
129
Commands for Checking T1 or E1 IMA Performance
129
Table 8-2 Descriptions of IMA Command Output
129
Checking Line Status with the Imalines Command
130
Checking Group Status with the Imagroups Command
130
Testing Connectivity with the IMA-TPP Command
131
T1 and E1 Module Specifications
131
Specifications Common to T1 and E1 Line Modules
132
Table 8-3 T1 and E1 Module Common Specifications
132
Specifications Unique to T1 Line Modules
133
Table 8-4 T1-Specific Specifications
133
Specifications Unique to E1 Line Modules
134
Compliance with IMA Specifications
134
Table 8-5 E1-Specific Specifications
134
Table 8-6 IMA Specifications
134
Compliance with ATM Specifications
136
Table 8-7 ATM Specifications
136
Chapter 9 Configuring an OC3-ATM Trunk Module
137
Installing an OC3-ATM Trunk Module
137
Connecting an OC3-ATM Trunk Module
137
Interpreting OC3-ATM Status Lights
138
Figure 9-1 Connecting an OC3-ATM Trunk Module
138
Figure 9-2 OC3-ATM Trunk Module
138
Table 9-1 DS3-ATM Trunk Module Status Lights
138
Configuring an OC3-ATM Trunk Module
139
Overview of OC3-ATM Settings
139
Displaying OC3-ATM Status and Nailed Groups
141
Changing Physical-Layer Interface Settings
141
Call Control
141
Table 9-2 Descriptions of Atmtrunks Command Output
141
Example of OC3-ATM Configuration
142
Checking OC3-ATM Trunk Interface Status
142
Monitoring the OC3 Interface
142
Monitoring Errors and Performance of the SONET Payload
145
SONET Performance and Error Counters
145
Performance-Monitoring and Interval-Performance-Monitoring Subprofiles
146
Figure 9-3 SONET Layers
146
OC3-ATM Trunk Module Specifications
148
Module Specifications
148
Table 9-3 OC3-ATM Module Specifications
148
Cable Specifications
150
Table 9-4 OC3-ATM Cable Specifications
150
Chapter 10 Configuring a DS3-ATM Trunk Module
151
Installing a DS3-ATM Trunk Module
151
Connecting a DS3-ATM Trunk Module
151
Interpreting DS3-ATM Status Lights
152
Figure 10-1 Connecting a DS3-ATM Trunk Module
152
Figure 10-2 DS3-ATM Trunk Module Front Panel
152
Configuring a DS3-ATM Trunk Module
153
Table 10-1 DS3-ATM Trunk Module Status Lights
153
Displaying DS3-ATM Port Status and Nailed Groups
155
Setting DS3 Framing Formats
155
Call Control
156
Example of DS3-ATM Configuration
156
Checking DS3-ATM Trunk Interface Status
157
Traffic Aggregation with the DS3-ATM Module
158
DS3-ATM Traffic Aggregation Connection
159
Aggregation Failure Protection with the DS3-ATM Bypass Feature
159
Figure 10-3 DS3-ATM Traffic Aggregation Connection
159
DS3-ATM Trunk Module Specifications
160
Table 10-2 DS3-ATM Trunk Module Specifications
160
Appendix A Stinger MRT Intended Use
163
User Line Interfaces
163
Network Interfaces
163
Administrative Interfaces
164
Appendix B Cables and Connectors
164
CONSOLE Port and Cable Pinouts
165
Alarm Connector Pinouts
165
Ethernet Interface Specifications
165
Table B-1 CONSOLE Serial Port and Cable Pinouts
165
Table B-2 Alarm Input Pinouts
166
STS-3 Connector Specifications
167
Table B-3 RJ-45 Connector (Normal End
167
Table B-4 RJ-45 Connector (Crossover End
167
50-Pin Telephone Company Connector Cable Specifications
168
Pinouts for Subscriber Line DSL Connections
168
Figure B-1 USOC RJ-21X 50-Pin Connector
168
Table B-5 Cable Pinouts for the LINE 1-24 Connector
168
Table B-6 Cable Pinouts for the LINE 25-48 Connector
169
Pinouts for POTS Connections to a Voice Switch
171
Table B-7 Cable Pinouts for the POTS 1-24 Connector
171
Table B-8 Cable Pinouts for the POTS 25-48 Connector
172
T1 and E1 Connector and Cable Specifications
173
T1 and E1 Connector Specifications
173
T1 and E1 Cable Specifications
173
Table B-9 Transmit and Receive Pins Assignments for T1 and E1 Trunk Module Connectors
173
T1 or E1 Crossover Cable: RJ-48C/RJ-48C
174
Figure B-2 RJ-48C/RJ-48C Crossover Cable
174
Table B-10 RJ-48C/RJ-48C Crossover Cable Specifications
174
T1 or E1 Straight-Through Cable: RJ-48C/RJ-48C
175
Figure B-3 RJ-48C/RJ-48C Straight-Through Cable Specifications
175
Table B-11 RJ-48C/RJ-48C Straight-Through Cable Specifications
175
T1 or E1 Straight-Through Cable: RJ-48C
176
Figure B-4 RJ-48C/DB-15 Straight-Through Cable
176
Table B-12 RJ-48C/DB-15 Straight-Through Cable Specifications
176
T1 or E1 Crossover Cable: RJ-48C
177
Figure B-5 RJ-48C/DB-15 Crossover Cable
177
Table B-13 RJ-48C/DB-15 Crossover Cable Specifications
177
T1 or E1 Straight-Through Cable: RJ-48C/Bantam
178
Table B-14 RJ-48C/Bantam Straight-Through Cable Specifications
178
T1 or E1 RJ-48C-Loopback Plug
179
Table B-15 RJ-48C-Loopback Plug Specifications
179
Appendix C Safety-Related Electrical, Physical, and Environmental Information
181
Electrical and Electronic Information
181
Electronic and Electrical Specifications
181
Table C-1 Stinger MRT Electronic and Electrical Specifications
181
USOC Jack and Code Information
182
Table C-2 Stinger MRT T1 and E1 Module USOC Jacks and Codes
182
ADSL Line Ringer Equivalence Number (REN
183
EMI Class
183
Minimum Ground Wire Size
183
Table C-3 Stinger MRT Minimum Ground Wire Sizes
183
Physical Specifications
184
Site Specifications
184
Operating Environment
184
Table C-4 Stinger MRT Physical Specifications
184
Table C-5 Stinger MRT Site Specifications
184
Space Requirements
185
Index
187
Advertisement
Advertisement
Related Products
Lucent Technologies Stinger MRT-AD-36S
Lucent Technologies Stinger MRT-AD-36S-4T1
Lucent Technologies Stinger MRT-AD-36S-8T1
Lucent Technologies Stinger MRT-AD-36S-4E1
Lucent Technologies Stinger MRT-AD-36S-2OC3
Lucent Technologies Stinger MRT-AD-36S-2DS3
Lucent Technologies Stinger
Lucent Technologies Stinger MRT
Lucent Technologies Stinger MRT 19
Lucent Technologies Stinger MRT 23
Lucent Technologies Categories
Telephone
Switch
Conference System
Software
Telephone System
More Lucent Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL