Config | Redundancy - Comtech EF Data LPOD PS 1.5 Installation And Operation Manual

Outdoor amplifier/block up converter buc, for firmware ver. 1.5.6 or higher
Hide thumbs Also See for LPOD PS 1.5:
Table of Contents

Advertisement

LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Ethernet Interface Operation

4.5.3.4 Config | Redundancy

Appendix A. 1:1 REDUNDANCY
Click [Refresh] to see the latest page data.
Figure 4-16. 'Config | Redundancy' Page
Enable Redundancy Switch Mode
Use the drop-down list to select the Switch Mode as follows:
• Off disables redundancy.
• 1:1 Red TX enables 1:1 redundancy with transmit switch control.
• 1:1 Red TX+RX enables 1:1 redundancy with transmit and receive switch
control.
• Manual enables manual redundancy mode.
Click [Change] to save.
Online Status (read-only)
The active status for the unit displays here Online or Offline.
Force Online
Click [Force Online] to force a unit to go active (online).
4–25
MN-LPOD
Revision 14