LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Serial Interface Operation
Controller-to-Target
Instruction Code and
Parameter Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Retrieve Next 5
N/A
RNE?
unread stored
Events
Arguments for
Command or
Query
75 bytes
Query only.
Returns the oldest 5 Stored Events that have not yet been read over the remote interface, in the form {CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body, where Sub-body is in the form ABCCddmmyyhhmmss:
A=Fault/clear indicator where F=Fault, C=Clear, I=Info
B=Fault type where 1=Unit, 2=RF, 3=Log
CC=Fault Code numbers, as in RAS? or Info Codes:
RAS FAULT CODES MAP AS FOLLOWS:
1)
P24V1
2)
P13VT
3)
A10V1
4)
A10VPS
5)
P5V8T
6)
P2V5T
7)
P1V2T
8)
N5V8T
9)
P7V8T
10)
FANR1
11)
FANR2
12)
ATEMP
13)
SHTDN
14)
IICST
15)
FWPWR
16)
CHKSM
17)
FPGAD
18)
BUCLD
19)
CHKSUM
20)
FPGAD
21)
BUCLD
22)
REFLD
23)
LNBCS
24)
SWIT
INFO CODES REPORT AS FOLLOWS:
0=Power Off; 1=Power On; 2=Log Cleared; 3=Global Config Change; 4=Redundancy Config Change
ddmmyy=Date in day/month/year format
hhmmss=Time in hour:minutes:seconds format
NOTES:
1)
If less than 5 events are retrieved, the remaining positions are padded with zeros.
2)
If there are no new events, the response is RNE*.
3)
A Global Config Change is defined as any time a command is successfully executed.
4)
A query does not set the status change flag. The status change flag is cleared after being read. No other events
toggle a status change.
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
5–27
MN-LPOD
Revision 14
Target-to-Controller
(see Description of Arguments)
Response to
Response to
Command
Query
RNE=
RNE={CR}ABCC
ddmmyyhhmm
ss{CR}ABCCdd
mmyyhhmmss{
CR}ABCCddmm
yyhhmmss{CR}
ABCCddmmyyh
hmmss{CR}ABC
Cddmmyyhhm
mss