Comtech EF Data LPOD PS 1.5 Installation And Operation Manual page 141

Outdoor amplifier/block up converter buc, for firmware ver. 1.5.6 or higher
Hide thumbs Also See for LPOD PS 1.5:
Table of Contents

Advertisement

LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Serial Interface Operation
Controller-to-Target
Instruction Code and
Parameter Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Auto Fault
AFR=
AFR?
Recovery
RF Power
AMP=
AMP?
Amplifier State
Attenuation
AOF=
AOF?
Offset
Attenuation
ATT=
ATT?
Arguments for
Command or
Query
1 byte
Command or Query.
Sets or returns automatic fault recovery in the form x, where:
0=Disabled
1=Enabled (DEFAULT)
NOTES:
1)
If auto fault recovery is enabled, it causes the output to return to its pre-fault mute condition if all faults are
cleared. If disabled, the output remains muted even if all faults are cleared. The LPOD output automatically
mutes if one of the following fault conditions occur:
• BUC lock detect fault
• LNB current fault
• LNB voltage fault
2)
These faults can be user defined as faults, alarms, or masked (see MSK command for more info).
COMMAND EXAMPLE: <0001/AFR=1{CR}
1 byte
Command or Query.
Sets or returns the RF power amplifiers status in the form x, where:
0=Off (DEFAULT)
1=On
NOTE: Turning the amplifier off disables the +10V supply, and masks it during fault checking.
COMMAND EXAMPLE: <0001/AMP=1{CR}
5 bytes
Command or Query.
Sets or returns the attenuation offset level in the form xx.xx, where:
xx.xx=00.00 (DEFAULT) to 20.00, in dB, in 0.25 dB steps
NOTE: This value is not copied to the offline unit in a redundancy system, but is added to the attenuation value upon
a switchover. This provides a unit-specific fine-tune to maintain power levels appropriately in a redundancy system.
COMMAND EXAMPLE: <0001/AOF=12.25{CR}
5 bytes
Command or Query.
Sets or returns the attenuation level in the form xx.xx, where:
xx.xx=00.00 to 20.00, in dB, in 0.25 dB steps
Default value: 10.00
COMMAND EXAMPLE: <0001/ATT=12.25{CR}
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
5–11
MN-LPOD
Revision 14
Target-to-Controller
(see Description of Arguments)
Response to
Response to
Command
Query
AFR=
AFR=x
AFR?
AFR*
AMP=
AMP=x
AMP?
AMP*
AOF=
AOF=xx.xx
AOF?
AOF*
ATT=
ATT=xx.xx
ATT?
ATT*