Comtech EF Data LPOD PS 1.5 Installation And Operation Manual page 112

Outdoor amplifier/block up converter buc, for firmware ver. 1.5.6 or higher
Hide thumbs Also See for LPOD PS 1.5:
Table of Contents

Advertisement

LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
Ethernet Interface Operation
• Attenuation Offset – Enter a valid offset value, in dB.
• Fault Recovery – Use the drop-down list to select Automatic or Manual.
• Mute – Use the drop-down list to select Enabled or Disabled.
• Aux Mute – Use the drop-down list to select Enabled or Disabled.
• Offline Mute – Use the drop-down list to select Enabled, Disabled,
MuteRx, MuteTx, MuteRx+LNB, MuteTx+LNB, Mute Tx+Amp, or Mute
Tx+LNB+Amp.
Click [Reset] to restore the previously saved settings.
Click [Change Configuration] to save any changes.
Reference
• Ref Freq Adjust – Enter a valid reference oscillator tuning voltage value
from 0 to 255. The default value is set to 87.
• Ext Ref Mute – Use the drop-down list to select the External Reference
Not Present Mute Mode as either Enabled or Disabled.
Click [Reset] to restore the previously saved settings.
Click [Change Configuration] to save any changes.
Low Power Forward Threshold (dBm)
When the forward power monitor is set to Alarm or Fault instead of the factory
default of Mask, and the forward power drops below the specified value, the
alarm/fault occurs.
Set the threshold value, in dBm, for the low forward power alarm/fault.
To disable the threshold, set this parameter to the default value of 00.00.
Click [Change] to save any changes.
FSK Address
Set the FSK (Frequency Shift Keying) Address from 01 to 15.
Click [Change] to save any changes.
4–20
MN-LPOD
Revision 14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lpod ps 1Lpod ps 2Lpod

Table of Contents